Access from the user program
KL3361 and KL3362
62
Version: 2.2.0
R39: Index register 2 for input data
The content of this register (default value: 0x8010) determines which date is shown in the process data
register
•
of oscilloscope terminal KL3361
•
of oscilloscope terminal KL3362
Index register 1 for process input data [
for indices).
R40: Trigger unit 1, trigger logic
Bit
Operation mode Value
Explanation
Default
R40.15
-
-
reserved
0
bin
R40.14,
R40.13,
R40.12
enableSource
000
bin
Trigger always enabled
000
bin
001
bin
Trigger activated, if signal at analog
input 1 above
Analog input 1 is in
• KL3361: the input for differential
voltage of the measuring bridge in
KL3361 (
• KL3362: oscilloscope input
)
010
bin
Trigger activated, if signal at analog
input 1 below
011
bin
Trigger activated, if signal at analog
input 2 above
Analog input 2 is in
• KL3361 not available
• KL3362: oscilloscope input
)
100
bin
Trigger activated, if signal at analog
input 1 below
101
bin
Trigger enabled if trigger input (24 V trigger) on high potential.
110
bin
Trigger enabled if trigger input (24 V trigger) on low potential.
R40.11,
R40.10
TriggerSource
00
bin
Timer with switching threshold 1
11
bin
01
bin
first analog input (IN1), with
10
bin
second analog input (IN2), with
(KL3362 only)
11
bin
Digital input
R40.9,
R40.8
Trigger mode
00
bin
Shot: The trigger is activated with an edge of bit
bEnableTrigger
of control
byte 1 (CB1.0), if enableSource is set.
01
bin
01
bin
Edge: The trigger is triggered via the edge selected via TriggerSource and
bLogic, if it is enabled via enableSource.
10
bin
Glitch: The trigger is triggered via the pulse selected via TriggerSource, bLogic
and bLarger, if it is enabled via enableSource.
R40.7
-
-
reserved
0
bin
R40.6
bTriggerWinEn
1
bin
The trigger condition for the following trigger unit must arrive within the
trigger time for trigger unit 1 [
. Otherwise everything is reset
0
bin
R40.5
bStartScopeRec
0
bin
The trigger event causes the downstream trigger unit to be enabled
0
bin
1
bin
The trigger event causes the recording to be started
R40.4
bTriggerOutEn
1
bin
The trigger event causes the digital output to be set, if this is enabled through
bit 2 of control byte 1 (CB1.2).
0
bin
R40.3
bLatchtimer
1
bin
The trigger event causes the current value of the running timer to be stored.
0
bin
R40.2
bResetTimer
1
bin
The trigger event causes the timer to be reset to zero. The timer will start run-
ning again automatically immediately.
0
bin
R40.1
bLarger
0
bin
in glitch mode: pulse width less than
0
bin
1
bin
in glitch mode: pulse width greater than
R40.0
bLogic
0
bin
in edge mode (edge triggering): falling
edge
in glitch mode: negative pulse
1
bin
1
bin
in edge mode (edge triggering): rising
edge
in glitch mode: positive pulse
R41: Trigger unit 1, switching threshold 1