Mounting and wiring
KL3361 and KL3362
26
Version: 2.2.0
3.6
Connecting the KL3362
WARNING
Risk of injury through electric shock and damage to the device!
Bring the Bus Terminals system into a safe, de-energized state before starting mounting, disassembly or
wiring of the Bus Terminals.
Fig. 13: Connecting the KL3362
The diagram shows the connection of two function generators (FG1, FG2) to the channels of the KL3362
oscilloscope terminal.
Terminal point
No.
Connection
+ 24V
1
Supply voltage for digital output
OUT 24V
2
Digital output
IN 1
3
Oscilloscope input channel 1 ( -10 V to +10 V)
GND
4
Ground for oscilloscope input channel 1 (internally connected with
terminal no. 8)
24V Trigger
5
Trigger input
0V
6
Ground for trigger input
IN 2
7
Oscilloscope input channel 2 ( -10 V to +10 V)
GND
8
Ground for oscilloscope input channel 2 (internally connected with
terminal no. 4)