Commissioning
EL72x1-901x
128
Version: 1.9
• Increase the value, until the motor starts to oscillate slightly. Then reduce the value by 80%.
5.3.4
NC settings
(Master TwinCAT 2.11 R3)
The data given here serve as an example for a servomotor type AM8122-0F20-0000 from Beckhoff
Automation. For other motors the values may vary, depending on the application.
Table of contents
• Selecting the maximum velocity [
- Calculation of the scaling factor [
• Commissioning the motor with the NC [
Several important parameters are required for the commissioning with the NC. These should be set as
follows before commissioning. A fundamental factor for setting the following parameters is the unit in which
the NC is set to operate. For the following parameters it was assumed that one revolution corresponds to
360°.
Definition of the unit
The unit can be defined in the
Settings
tab for the axis.
Fig. 159: Definition of the unit
Summary of Contents for EL72 1-901 Series
Page 2: ......
Page 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Page 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Page 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Page 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Page 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Page 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Page 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...