Operation
EL6900
56
Version: 2.2.0
4.5.3
Cycle time of the safety project
Index 1C32
hex
: Cycle Time Measuring
Index
Name
Meaning
Flags
Default
1C32:05 Minimum cycle
time
Minimum cycle time in ns that should be set by
EtherCAT. Corresponds to the maximum program
running time of the EL6900.
RO
00000000
hex
1C32:08 Command
Cycle time measurement is activated by setting the
command to 0001hex.
This value should be reset to
0 once the cycle time has been determined.
RW
0000
hex
4.5.4
Status LEDs
The LEDs State 1 to State 4 indicate the current status of the EL6900.
Fig. 53: EL6900 status LEDs
State 1
State 2
State 3
State 4
Meaning
off
off
off
lit
• No project present on the terminal
off
off
lit
lit
• Project present on the terminal
• EtherCAT status: Pre-Operational (Pre-OP)
lit
lit
lit
lit
• Project present on the terminal
• EtherCAT status: Operational (OP)
4.6
Maintenance
Maintenance
The TwinSAFE components are maintenance-free!
Environmental conditions
WARNING
Observe the specified environmental conditions!
Please ensure that the TwinSAFE components are only stored and operated under the
specified conditions (see technical data).
If the TwinSAFE component is operated outside the permitted temperature range it will switch to
Global
Shutdown
state.
Cleaning
Protect the TwinSAFE component from unacceptable soling during operation and storage!
If the TwinSAFE component was subjected to unacceptable soiling it may no longer be operated!
Summary of Contents for EL6900
Page 1: ...Operating Instructions for EL6900 TwinSAFE Logic Terminal 2 2 0 2017 05 10 Version Date...
Page 2: ......
Page 34: ...Operation EL6900 34 Version 2 2 0 Fig 18 Creating a TwinSAFE group...
Page 37: ...Operation EL6900 37 Version 2 2 0 Fig 22 Appended Emergency Stop block...
Page 59: ...Appendix EL6900 59 Version 2 2 0 5 2 Certificates...