![Beckhoff CX1020 Series Hardware Documentation Download Page 57](http://html1.mh-extra.com/html/beckhoff/cx1020-series/cx1020-series_hardware-documentation_2719440057.webp)
Product
overview
Embedded PC
55
CX1100-00x3 connections
This power supply unit permits not only the connection of the Beckhoff Bus Terminals, but also the serial connection
of the Beckhoff fieldbus box modules of the type extension box IExxxx. The power is supplied via the upper spring-
loaded terminals labeled “24V” and “0V”.
The supply voltage feeds the CX system and, over the K-Bus, the Bus Terminals. Since the K-Bus does no more
than pass data on, a further power supply is necessary for the Bus Terminals. This is provided by means of the
power contacts, which are not connected to the power supply.
CX1100-0003 for CX1000, CX1010 und CX1020
CX1100-0013 for CX1030
Fieldbus connection:
Plug the IP link connector into the respective connections, i.e. one fibre-optic cable each into IN (x03) and OUT (x04).
You then connect the other end with the corresponding IP link interface of the extension box. The connection must be
made so that the output of the fieldbus connection is connected to the input of the extension box and vice versa.
LED:
With proper connection of the power supply unit and with power supply turned on, the power LED (PWR) lights up
green. In the case of a short-circuit, it lights up red. The I/O LEDs display the operation status of the Bus Terminals.
Error-free start-up of the configuration is signaled by the red "I/O ERR" LED being extinguished. If the ”I/O ERR" LED
blinks, an error in the area of the terminals is indicated. The error code can be determined from the frequency and
number of blinks.
PE power contacts
The ”PE" power contact must not be used for other potentials.
Summary of Contents for CX1020 Series
Page 2: ......
Page 5: ...Table of contents Embedded PC 3 Certifications 118 Support and service 119...
Page 62: ...Assembly and connecting 60 Embedded PC CX1000 N00x CX1020 N0x0 System interfaces...
Page 65: ...Assembly and connecting Embedded PC 63 CX1100 09x0 UPS modules CX1100 0900 CX1100 0910...
Page 66: ...Assembly and connecting 64 Embedded PC CX1100 0920...
Page 68: ...Assembly and connecting 66 Embedded PC CX1500 Mxxx...