Product overview
CP69xx
13
Version: 3.0
3.2.4
USB output
The Control Panel has two USB outputs (X104, X105) with socket type A. The interfaces are used to connect
peripheral devices with USB connection. USB specification 2.0 is supported.
1 2 3 4
4
3
2
1
X104
X105
Fig. 6: CP69xx_USB output pin numbering
Table 5: USB interface pin assignment
Pin
Connection
Shield
GND
1
Vbus
2
D -
3
D +
4
GND
3.2.5
Power supply
The Control Panel is supplied with a nominal input voltage of 24 V
DC
. The power supply and the protective
earth of the device are connected via the 5-pin voltage socket (X106).
X106
1
2
3
4
5
Fig. 7: CP69xx_voltage socket pin numbering
Table 6: Voltage socket pin assignment
Pin
Signal
Description
1
NC
not used
2
NC
not used
3
Protective earth
4
-
24 V power supply, negative pole
5
+ 24 V
24 V power supply, positive pole
The plug for the power supply is specified for 16 A and can accommodate wire cross-sections of up to
1.5 mm
2
. For long supply lines, use 1.5 mm
2
cables to achieve a low voltage drop on the supply line. There
should be at least 22 V at the power supply plug of the Control Panel, so that the Control Panel remains
switched on during voltage fluctuations. The plug is included in the delivery. You can obtain a replacement
plug from your Beckhoff Sales using the following ordering option:
• C9900-P927: power supply connector for CP69xx Control Panel, 5-pin connector with strain relief for
the external supply cable