background image

General instructions 

 

 

General instructions 

 

Notes on the Documentation 

 

This description is only intended for the use of trained specialists in control 
and automation engineering who are familiar with the applicable national 
standards. It is essential that the following notes and explanations are 
followed when installing and commissioning these components. 
 

 

Liability Conditions 

 

The responsible staff must ensure that the application or use of the 
products described satisfy all the requirements for safety, including all the 
relevant laws, regulations, guidelines and standards. 

The documentation has been prepared with care. The products described 
are, however, constantly under development. For that reason the 
documentation is not in every case checked for consistency with 
performance data, standards or other characteristics. None of the 
statements of this manual represents a guarantee (Garantie) in the 
meaning of § 443 BGB of the German Civil Code or a statement about the 
contractually expected fitness for a particular purpose in the meaning of 
§ 434 par. 1 sentence 1 BGB. In the event that it contains technical or 
editorial errors, we retain the right to make alterations at any time and 
without warning. No claims for the modification of products that have 
already been supplied may be made on the basis of the data, diagrams 
and descriptions in this documentation. 

© This documentation is copyrighted. Any reproduction or third party use of 
this publication, whether in whole or in part, without the written permission 
of Beckhoff Automation GmbH, is forbidden. 
 

 

Description of safety symbols 

 

The following safety symbols are used in this operating manual. They are 
intended to alert the reader to the associated safety instructions. 
 

 

Danger

 

 

This symbol is intended to highlight risks for the life or health of personnel. 

 

 

 

 

Warning

 

 

This symbol is intended to highlight risks for equipment, materials or the 
environment. 

 

 

 

i

 

Note

 

 

This symbol indicates information that contributes to better understanding. 

 

 

2

 

CP63XX 

Summary of Contents for CP63 Series

Page 1: ...Installation and Operating instructions for Built in Panel PC CP63xx Version 1 3 Date 2006 01 11...

Page 2: ......

Page 3: ...npacking 8 Installation of the PC in the control cabinet 9 Earthing measures 9 Power supply 10 Connecting devices 11 Connecting cables 11 Verifying the voltage and connecting 11 Operating Instructions...

Page 4: ...he meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains...

Page 5: ...equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been...

Page 6: ...National regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machin...

Page 7: ...plant engineering applications Structure Opening the housing To open the PC housing release the screw 1 by one turn using a screwdriver The plastic cap 2 can be then be pulled forward thereby releasi...

Page 8: ...asic configuration The computer chassis can now be removed from the housing The power supply 1 and the hard disk 2 are located in the lower part of the chassis The slot motherboard 3 is located in the...

Page 9: ...o be used while a PC keyboard can be connected to the lower PS 2 connector 7 VGA connection VGA A 15 pin SUB D socket connector 5 allows a VGA monitor to be connected free slot free slot A free slot 7...

Page 10: ...ns in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur...

Page 11: ...e unit is in its mounting position the ventilation openings must not be obstructed Warning Extreme environmental conditions should be avoided as far as possible Protect the rear of your PC from dust h...

Page 12: ...ower supply unit Output voltages from the 24 V power supply unit Current loading maximum 5 V 8 A 5 V 0 5 A 12 V 4 A 12 V 0 5 A 3 3 V 4 A 5 V VSB 0 5 A Pin assignment and fuse protection Pin assignment...

Page 13: ...ces that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Conn...

Page 14: ...software is writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by swit...

Page 15: ...as to be replaced according to the rules of the board manufactorer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufactur...

Page 16: ...incorrect Other cause Remove floppy disk or CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault...

Page 17: ...C Beckhoff Support Support offers you comprehensive technical assistance helping you no only with the application of individual Beckhoff products but also with other wide ranging services world wide s...

Page 18: ...re to be observed during transport and storage as in operation The shock resistance during transport can be improved by means of suitably packing the Industrial PC The ambient temperature during stora...