Product overview
CP39xx
16
Version: 3.1
3.3.1
Power supply
The Control Panel is supplied with a nominal input voltage of 24 V. The connection to the power supply and
the external wiring of the Control Panel is established via the 4-pin M12 socket (X101) with IP65 protection.
If the Control Panel is connected to an Industrial PC via the CU8803 transmitter box, no additional power
supply to the Control Panel is required via the voltage socket.
1
2
3
4
X101
Fig. 11: CP39xx_voltage socket pin numbering
Table 6: Voltage socket pin assignment
Pin
Signal
Description
1
+ 24 V
Power supply
2
GND
0 V
3
GND
0 V
4
+ 24 V
Power supply
The plug for the power supply is specified for 16 A. Due to the dual connection, maximum wire cross-
sections of 4 x 0.75 mm
2
can be accommodated. For long supply lines, use 4 x 0.75 mm
2
cables to achieve a
low voltage drop on the supply lines. There should be at least 22 V at the power supply plug of the Control
Panel, so that the Control Panel remains switched on during voltage fluctuations. The plug is included in the
delivery. You can obtain a replacement plug from your Beckhoff Sales using the following ordering option:
• C9900-P916: Power supply connector for CP39xx, round connector IP65 with strain relief for the
external supply cable
3.3.2
CP-Link 4 input
The CP39xx-0010 Control Panel has a CP-Link 4 input (X102) in the form of an 8-pin M12 socket. Via the
interface the Control Panel can be connected to an Industrial PC over a distance of up to 100 m. The
connection can be made either directly with an Industrial PC with a corresponding PCIe module or indirectly
via an intermediate transmitter box.
X102
1
2
3
4 5
6
7
8
Fig. 12: CP39xx-0010_CP-Link 4 pin numbering
Table 7: CP-Link 4 pin assignment
Pin
Signal
Pin
Signal
1
7
HDBT_2-
2
HDBT_0-
8
3
S1
Shield
4
HDBT_1-
S2
Shield
5
S3
Shield
6
HDBT_3-