Decommissioning
CP39xx-14xx-0010
42
Version: 1.1
5
Decommissioning
NOTE
Hardware damage due to power supply
A connected power supply can cause damage to the Control Panel during disassembly.
• Disconnect the power supply from the device before starting to disassemble it.
When taking the Control Panel out of operation, you must first disconnect the power supply and cables.
Afterwards, you can dismount the device from the mounting arm.
If you do not want to continue using the Control Panel, Chapter 5.2
provides information on the correct disposal of the device.
5.1
Disconnecting the power supply and cables
CAUTION
Risk of electric shock
Disconnecting the Control Panel during a thunderstorm can lead to electric shock.
• Never disconnect the cables of the Control Panel during a thunderstorm.
NOTE
Hardware damage due to power supply
Disconnecting the CP-Link 4 connection while the transmitter box power supply is switched on may cause
damage to the transmitter box.
• Switch off the power supply to the CU880x transmitter box before disconnecting the CP-Link 4 connec-
tion.
Before removing the Control Panel, you must follow the steps below:
1. Shut down the Control Panel.
2. Disconnect the Control Panel from the power supply (see below).
3. Disconnect the data transfer cables between the Control Panel and the connected devices.
Disconnect the power supply
Proceed as follows to disconnect the power supply:
1. Disconnect the Control Panel from the external 24 V power supply.
2. Loosen the screw connection between the voltage socket and the voltage connector.
3. Remove the voltage connector from the voltage socket.
4. Disassemble the power cable if the connector is to remain with the Panel.
Disconnecting cables
To disconnect the cables from the Control Panel, proceed as follows:
1. Make a note of the wiring configuration, if you wish to restore it with another device.
2. Disconnect all data transfer cables from the Control Panel.
3. Finally, disconnect the ground connection.
5.2
Disassembly and disposal
Before you can remove the Control Panel from the mounting arm tube, you must first remove the side panels
and disconnect the power supply and the cables (see chapter 5.1