Product Description 

 

2 Product Description 

2.1 Product overview 

 

 
The high-performance multi-touch Panel PC 

With the CP32xx series, a high-end Panel PC with multi-touch can be used directly in the field. The 
devices in a slender aluminium housing feature complete IP 65 protection and are designed for mounting 
arm installation. The Panel PCs offer maximum computing power with processors of the latest generation, 
such as Intel® Celeron® or Core™ i3, i5, or i7. 

A choice of seven different multi-touch TFT displays in sizes between 12-inch and 24-inch and 4:3, 
widescreen, landscape or portrait formats are available. Cooling is achieved by means of cooling fins on 
the outer wall as well as fans inside the closed housing. The operating temperature range is 0 to 45 °C. 

The Panel PC features an integrated rotatable and tiltable mounting arm adapter for a 48 mm diameter 
mounting arm tube. There is a choice of attaching the mounting arm from above or below. The connecting 
cables are laid through the mounting arm. The Industrial PC connections (up to six) with IP 65 connectors 
are positioned in the large wiring space and are easily accessible. The wiring area can be opened easily 
without dismounting the device from the mounting arm, offering fast access to the IP 65 connectors for 
power supply, Ethernet and optional fieldbus, USB or RS232. Prefabricated cables in various lengths are 
available for all connections. The C32xx series Panel PCs are supplied with a 24 V power supply unit, 
optionally with integrated uninterruptible power supply (UPS). A battery pack can be connected externally 
and installed on a DIN rail in the control cabinet. 

The CP32xx Panel PCs are equipped with one or two hard disks, SSDs or CFast cards or combinations 
thereof. With the on-board RAID controller, two same hard disks, SSDs or CFast cards can be mirrored. 
The data media and the lithium battery of the system clock are accessible from the rear under the cover. 

There is a Mini PCI slot in the CP32xx. The Beckhoff Mini PCI Ethernet or fieldbus cards can be factory-
fitted. NOVRAM up to 512 kB is also available in the form of an optional Mini PCI plug-in card for fail-safe 
data storage. 

CP32xx 

Summary of Contents for CP32 Series

Page 1: ...Installation and Operating instructions for CP32xx Multi touch Panel PC Version 1 9 Date 2019 10 09...

Page 2: ......

Page 3: ...duct Description 7 2 1 Product overview 7 2 2 Appropriate Use 9 2 3 Access to the connectors 9 2 4 Access to the memory device and the battery 10 2 4 1 Removing the Cover 10 2 4 2 Replacing the batter...

Page 4: ...25 5 1 2 Shutting down and switching off 25 5 1 3 First switching on and driver installation 25 5 2 Operation 25 5 3 Servicing and maintenance 26 5 3 1 Cleaning 26 5 3 2 Maintenance 26 5 3 3 Replacin...

Page 5: ...XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate...

Page 6: ...duals Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safet...

Page 7: ...all parts of the equipment must first be switched off after which the Panel PC is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of the Panel...

Page 8: ...t open the housing of the Panel PC Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Industrial PC is used national...

Page 9: ...ugh the mounting arm The Industrial PC connections up to six with IP 65 connectors are positioned in the large wiring space and are easily accessible The wiring area can be opened easily without dismo...

Page 10: ...mounting arm adapter for Rittal and Rolec mounting arm systems with 48 mm tube Passive cooling through heat sink internal fan for equal heat distribution to all the walls of the housing Wiring area f...

Page 11: ...ned for mounting arm installation Risk of explosion Danger The Control Panel must not be used where there is a risk of explosion 2 3 Access to the connectors The connectors of the Panel PC are located...

Page 12: ...d through the mounting arm tube before connecting them in the connection area The installation of the cover takes place in reverse order 2 4 Access to the memory device and the battery The slots for t...

Page 13: ...e pulled out Here changing the lithium battery is also possible The installation takes place in reverse order 2 4 2 Replacing the battery Danger of Explosion WARNING Replace battery only with the iden...

Page 14: ...accords to the IP65 standard Wiring when using 8 core cables Pin Wire Function Pin Wire Function 1 1 7 6 PC_ON 2 2 Battery Pack with UPS 8 7 Power Status 3 3 NC 9 NC 4 ge gn 10 NC 5 4 11 NC 6 5 24 V D...

Page 15: ...r set according to IEC24702 white No 09 45 145 1500 The connector and special tools for the assembly are available via the company Harting http www harting de as well as different distributors 2 5 3 A...

Page 16: ...tch cabel Network cable with IP65 connector C9900 K281 Network cable for CP32xx or CP72xx length 3 m assembled Harting push pull Ethernet connector IP65 second end RJ 45 IP20 C9900 K282 Network cable...

Page 17: ...ture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hour...

Page 18: ...direct sunlight Avoid extreme environmental conditions Attention Extreme environmental conditions should be avoided as far as possible Protect the Panel PC from dust moisture and heat 4 1 Earthing me...

Page 19: ...e a diameter of 48 mm with a maximum tolerance of 0 1 mm 0 8 mm The mounting arm adapter enables to tilt the Panel PC at 20 and to rotate it about 165 Anti twist protection Note The mounting arm adapt...

Page 20: ...After feeding the connection cables of the Panel PC through the mounting arm tube the mounting arm tube will be positioned into the mounting arm adapter Insert the mounting arm tube all the way to the...

Page 21: ...Mounting 3 Tighten the Allen locking screw using the Allen key 2 2 4 Now the screw cap is tightened carefully clockwise using the hook wrench SW 58 62 3 3 CP32xx 19...

Page 22: ...e Industrial PC is provided with a power supply unit with integrated UPS order option you can realize an uninterruptible power supply UPS using the battery pack C9900 U330 Danger of Explosion WARNING...

Page 23: ...es an ON OFF switch for the machine Basically the main switch remains switched on and provides the power supply for the PC during shutdown Via the PC ON input of the power supply the PC gets the comma...

Page 24: ...assembled into the Industrial PC s power supply socket Then connect it to your external 24 V power supply Use same type of rechargeable battery Attention If a 24 V UPS is installed the same type of r...

Page 25: ...ording to the wiring diagram the circuit of PC_ON and Power Status is symbolical Connection of the Battery Pack and UPS Output Note Connection of the Battery Pack and UPS Output only in combination wi...

Page 26: ...the Panel PC from the power supply Connect all cables at the Panel PC and at the devices to be connected Ensure that all screw connections between connectors and sockets are tight Reconnect all devic...

Page 27: ...5 1 3 First switching on and driver installation When you switch on the Industrial PC for the first time the pre installed operating system optional will be started In this case all the required drive...

Page 28: ...tice correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be protected against sunlight and moisture The used battery...

Page 29: ...vers can be installed from the driver CD provided To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial PC Drive...

Page 30: ...ff Service Panel PC boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Panel PC Call the manufacturer of the...

Page 31: ...e Panel PC please visit our homepage Here you will find the actual drawings using the link http www beckhoff de german download technical_drawings htm Notice mounting orientation Warning The assembly...

Page 32: ...67 W UL compliance in progress Using a power supply class 2 or Fuse protection with 4 A according to UL 60950 2 chapter 2 5 table 2C Interfaces 1 x RJ 45 Ethernet 10 100 1000 Mbit Protection class IP...

Page 33: ...H Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical ass...

Page 34: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eq...