Commissioning
C6925
27
Version: 2.1
1
2
3
4
5
6
7
8
Battery
24 V
Power
24 V DC
+
U
P
S
+
+
P
C
_
O
N
P
o
w
e
r-
S
ta
tu
s
-
-
X2
X1
X1
X2
ext. switch
N0
N0
0 V
22-30 V DC
UPS Output
L max = 10 m
1,5 mm / AWG14
2
1
2
G
N
D
+
2
4
V
PTC
24 V/3,4 Ah
30 V/9 A
C9900-U330 battery pack
- +
Fig. 14: C6925_Wiring diagram
So that the Industrial PC still has a monitor output in case of a power failure, a Control Panel can be
connected to the UPS output of the power supply unit. Even after a power failure there is a voltage of 24 V
DC
between the UPS output and the negative pole of the battery pack. The maximum load is 1.4 A (max. 2.5 A
from year of manufacture 2016).
Once the PC has been de-energized via the UPS software, the UPS output is switched to 0 V. A connected
panel is switched off.
Summary of Contents for C6925
Page 1: ...Manual EN C6925 Industrial PC 9 14 2021 Version 2 1 ...
Page 2: ......
Page 4: ...Table of contents C6925 4 Version 2 1 ...
Page 46: ......