Installation Instructions
signal lamp connection or via a contactor. With this solution the main
switch generally only has to be switched off if the control cabinet has to be
opened. The battery will only be used in the event of a power failure.
In order to maintain a screen display for the Industrial PC in the event of a
power failure, the power supply unit is equipped with a UPS output 27 V /
1.4 A for connecting a Control Panel with a display dimension up to 19
inches. This enables a power failure to be visualized and displayed to the
user. Once the PC has shut down, the UPS output is switched off.
For a detailed functional description please refer to section
Connecting
24VDC Power Supply
.
Electrical Data
Input voltage:
22 – 30 V DC
Current consumption:
10 A (22 V)
Output capacity:
150 W (max.)
Current carrying capacity of
the 24 V power supply unit
Output voltages from the
24 V power supply unit
Current loading
maximum
+ 5 V
14 A
- 5 V
0.3 A
+ 12 V
12 A
- 12 V
0.5 A
+ 3,3 V
12 A
5 V VSB
1.5 A
Connecting the power supply
A 5-pin male plug connector with CAGE CLAMP connection (see photo) is
installed at the PC housing in order to connect the power supply and the
battery pack.
Pin assignment for
connecting the power
supply and the battery pack
Pin
Function
1
+
2
-
24V
DC
Power Supply
3
4
+
5
-
Battery Pack (with UPS)
Power Switch
The Industrial PC is switched on and off with an external power switch.
Therefore the PC is equipped with a 3-pole male plug connector with
CAGE CLAMP connection.
Pin assignment for
connecting the power switch
Pin
Function
1
Power-Status
2
PC_ON
3
24V
DC
Power Pole
5 4 3 2 1
1 2 3
C6240-1007
15