Installation Instructions
Power Supply Connection with
24 V
DC
power supply unit
Power supply unit
The Industrial PC is optionally fitted with a 24 V
DC
power supply unit .
Uninterruptible power supply (UPS)
Note
When the Industrial PC is provided with a power supply unit with
integrated UPS (order option) you can realize an uninterruptible power
supply (UPS) using the battery pack C9900-U330.
Danger of Explosion!
WARNING
Danger of Explosion if using other battery packs!
Beckhoff power supply technology
Schematic diagram of
power supply unit wirings
Innovative solution for
shutting down Industrial
PCs
Industrial PCs equipped with a UPS are in actual use frequently switched
off by simply turning off the supply voltage. In this case the PC shuts down
via the battery. However, over time this reduces the service life of the
battery.
The new Beckhoff power supply technology approach addresses this
problem and now offers the user the option of switching the PC off without
the need for using the battery, thereby reducing the load on the battery.
In addition to the main switch this innovative solution uses an ON/OFF
switch for the machine. Basically, the main switch remains switched on and
provides the power supply for the PC during shutdown. Via the PC ON-
input of the power supply the PC gets the command to shut down the
operating system.
Once the PC has shut down, the PC power supply unit sets the Power
Status-output (P-S) to 0, what indicates that the process is complete and
that the main voltage can be switched off. This can be done manually via a
14