Maintenance and cleaning
Version: 2.5
───
61
AG3300
10.2
Intervals
Under nominal conditions, the motor components have different op-
erating hours. We have provided you with a list of maintenance work
and intervals for the associated components below:
Component
Interval
Maintenance
Gear unit
During commission-
ing
Thereafter:
Every three months
Check gear unit for external damage and leaks
Check drive shaft and output shaft for foreign media such as oil
and dirt
Check gear unit for corrosion
Clamping screw
Motor attachment
During commission-
ing
Thereafter:
Every three months
Check tightening torques
Fastening screw
Gear unit housing
During commission-
ing
Thereafter:
Every three months
Check tightening torques
10.2.1
Lubrication
Notes on lubrication
Beckhoff gear units from the AG3300 series are lubricated for life.
The lubricant used does not have to be renewed.
If you wish to change the lubricant, contact Beckhoff Service.
All gear units are lubricated for life in the factory with a synthetic
polyglycol gear oil or with a high-performance grease.
Refer to the name plate for detailed information on lubrication. All
bearings are lubricated for life at the factory.
Further information on the lubricants can be obtained directly from
the manufacturer.