28100031
100 08/2017
Page: 13
2.6 Parameter overview
Parameters relating to the operational data
(The numerical values are continuously updated in display line 4!)
parameter
text in display line 3 meaning
no.
19-10 working hours [h]
FU working hours
19-11 motor hours [h] working hours of the motor/level
19-12 frequency [Hz] current frequency
19-13 mains voltage [V]
current mains voltage
19-14 motor current [A]
current consumption of motor at the moment
19-15 wattage [W]
current power consumption of unit
19-16 kWh-Counter total unit kWh
19-17 Number of power line switches number
19-19 software version
display software version
Parameters relating to the error log
(The numerical values are saved to display line 4 only in the actual event of an error!)
parameter
text in display line 3 meaning
no.
19-20 wh_error [h] working hours of the FU when the error occurred
19-21 mh_error [h] working hours of the motor/level when the error occurred
19-22 f_error [Hz]
frequency when the error occurred
19-23 U_error [V]
mains voltage when the error occurred
19-24 I_error [A]
current consumption when the error occurred
19-25 P_error [kW] power consumption when the error occurred
19-26 p_error [mbar] system pressure when the error occurred
19-27 bp_error
clamp where the error occurred
19-28 kWh-counter error kWh where the error occurred
19-49 error status error code for modem monitoring
19-50...19-77
ring buffer error history
Annotations of the error codes in Parameter 19-27 (binding post_error)
binding post meaning
no.
1
Vacuum / Pressure
Vacuum / Pressure too high
2
oil cooler fan oil cooler malfunction
3
oil pump
oil pump malfunction
4
op fan top fan malfunction
5
control transformer
control transformer malfunction
7
external motor fan
external motor fan malfunction
16
oil pressure transmitter low oil pressure (lower threshold value)
19
oil temperature switch oil temperature too high
29
oil floater switch
not enough oil in tank