10
Assembly and Operating Instructions
General
Warranty
Intended use
Safety information
The S10AF control is a quality product with many performance features and advantages.
Always observe these assembly and operating instructions when installing and setting the device.
Please read these instructions carefully before operation. Work on the electrical equipment must be performed by a qualified
electrician.
Please comply with the legal requirements (safety, accident prevention), particularly the regulations of the employers’ liability
insurance association (BGR 232) and EN 12453 “Safe use of power-operated doors”, as well as the applicable EN stand-
ards.
The system installer is responsible for correct assembly, instruction of the operator and for issuing of the CE mark.
The operator must ensure that the system is only operated in perfect condition and that the safety devices are regularly
checked by an expert. A damaged mains cable with CEE plug has to be replaced immediately by a qualified electrician. In the
case of roller doors, the system construction on site has to offer suitable protection for the curtain, so that if it is extended
beyond the end limits, it does not cause any dangerous situation and risk to life. The increased safety requirements of the
integrated operating elements result in 50,000 and 100,000 operations for deadman and self-locking operation respectively.
Installation instructions
The S 10 AF door control is a reverse contactor control unit for controlling Becker roller door drives with external brake and
mechanical limit switches. A safety edge mechanism in connection with an external evaluator is required for downward door
movement in self-locking mode.
Other applications, utilisation and modifications are not permitted in order to protect the safety of the users and others, since
these actions can impair the system’s safety, resulting in personal injuries and property damage. Becker-Antriebe shall not
accept liability for damages arising from such actions. Always observe the information in these instructions when operating or
repairing the system. Becker-Antriebe shall not accept liability for damages resulting from incorrect usage.
Structural modifications and incorrect installation which are not in accordance with these and our other instructions can
result in serious injuries, e.g. crushing of limbs. Therefore, structural modifications should only be carried out with our prior
approval and in accordance with our instructions, particularly the information contained in these Assembly and Operating
Instructions.
Any further processing of the products which does not comply with their intended use is not permitted.
The end product manufacturer and fitter have to ensure that all the current statutory, official regulations and, in particular,
EMC regulations are adhered to during utilisation of our products, especially with regard to end product assembly, installation
and customer advice.
Installing the control
1. Installing the control
The control device is intended for use indoors and is to be installed at the desired operating height. The housing cover with the
triple pushbuttons can be removed during installation by means of the plug-in connection (connector is retained and engages
audibly when fitted). During commissioning, the cover can be screwed on with just two screws so that it is laterally offset (open
housing facilitates operation of buttons).
2. Installing the supply point
Mount a CEE 16A/6h socket beneath the control or connect the control via a permanently laid installation cable. The control
must have all-pole protection against short circuits and overload provided by a fuse of max. 10A per phase.