69
2.8 Configuration
The configuration of the DVCS6100 can be changed and edited by using a personal computer or
laptop with the related software CSW6100.
Configuration Software (CSW6100)
•
The configuration software CSW6100 and the related user manual is part of the
configuration software set.
o
Details see "Accessories", page 32 - Configuration Software Set.
•
All data for REU6100 are stored in the REU6100 and the EM6100 if connected.
EM6100
With the power-on of the REU6100 all data from a connected external memory
module (EM6100) overwrites the existing data from the REU6100 internal
memory.
Before a replacement of a memory module (EM6100):
•
Save the already existing configuration data from REU6100 for security
reasons and for reuse with other devices.
2.8.2.1 Programming of the EM6100
For detailed information please read manual "CSW6100 ...".
(
www.becker-avionics.com/downloads/
→
Intercom).
2.9 Communication Interfaces
CANbus Protocol for REU6100
•
Use the CANbus protocol for control data interchange between REU6100 and ACU610X.
RS232/RS422 Protocol for REU6100
•
Use the RS232/RS422 protocol for data interchange between REU6100-X-(3XX) and
glass cockpit or between two REU6100-X-(3XX) as multi-REU application.
Details on request.