background image

Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information

The drive must be disconnected from its power source during cleaning and maintenance and when re-
placing parts.

All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.

Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have
been instructed in the safe use of the device, and have understood the hazards involved. Children must
not play with the device.

Systems have to be checked regularly by authorised specialists for wear and damage.

Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.

Do not operate equipment if people or objects are within the danger zone.

Observe the danger zone of the equipment during operation.

Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.

Caution

Safety instructions for avoiding serious injuries.

Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information

Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example,
the design of the operated product, the way the drive works in the situation it is installed in or even the
way the end product is mounted in the end user’s place of use cannot be taken into consideration by
the drive manufacturer. 
If any questions or uncertainties regarding the safety instructions contained in the standard arise,
please contact the manufacturer of the part or end product in question.

All applicable standards and regulations for electrical installation must be complied with.

All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by trained technicians, in particular qualified electricians.

Only use spare parts, tools and accessory devices which have been approved by the drive manufac-
turer. 
Unapproved third-party products or modifications to the system and its accessories represent a risk to
your safety and the safety of others. This means that the use of unapproved third-party products, or
modifications which have not been agreed with or approved by us, are prohibited. We do not accept li-
ability for damage or injury arising from such actions.

Position switch with OFF presetting within sight of the driven product, but away from moving parts, at a
height of over 1.5 m. This must not be publicly accessible.

Permanently mounted control devices must be positioned where they can be seen.

Rated torque and duty cycle must be suitable for the requirements of the driven product. 
Technical data - rated torque and service life can be found on the type plate of the tubular drive.

Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any
other surface from which the drive can be accessed.

To ensure safe operation of the system after commissioning, the limit positions must be correctly set/
programmed in.

Drives with a H05VV-F connecting cable may only be used indoors.

Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors.

To connect the drive to the driven part, solely mechanical accessory components made by the drive
manufacturer from the current product catalogue may be used. The components must be installed in
accordance with the manufacturer's instructions.

4 - en

Summary of Contents for M17

Page 1: ... mechanical limit switching Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 725 0a 23 05 2022 ...

Page 2: ...uctions for installation and commissioning 4 Intended use 6 Assembly 6 Setting the limit positions 8 Blockage detection when moving UP 8 Information for the electrician 9 Disposal 9 Maintenance 9 Technical data dia 45 9 What to do if 10 Sample wiring diagrams 10 Declaration of conformity 12 2 en ...

Page 3: ...avoided could result in injury ATTENTION ATTENTION indicates measures that must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications may only be carried o...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ... down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or protected When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 If the mains connecting cable is damaged it may only be replaced by the manufacturer If the drive has a plug in connecting cable it mu...

Page 6: ... Assembly Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only ...

Page 7: ...oove recesses have different sizes and allow the drive to fit exactly Y X For round shafts Measure the lug of the thrust ring X Y Then notch the tube on the motor side so the lug of the thrust ring can also be pushed into the shaft There must be no play between the lug of the thrust ring and the shaft 10 mm To ensure secure torque transmission for round shafts we recommend screwing the drive adapt...

Page 8: ...ntinuous operation and has only been designed for start up Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges Setting the limit positions A fixed stop at the upper limit position and fixed shaft connectors must be in place During commissioning and subsequent use ensu...

Page 9: ...ust not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN EXTEND and RETRACT If the drive is to be operated with devices which contain sources of interference the elec trician must ensure suitable interference supp...

Page 10: ...lar drive does not run in the right direction Check the electrical connection Tubular drive does not switch off properly at the lower limit pos ition Use fixed shaft connectors Tubular drive does not switch off properly at the upper limit po sition Fit a fixed stop Sample wiring diagrams The assignment of the black and brown wires according to the direction of travel is de pendent on how the drive...

Page 11: ...ual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 11 en ...

Page 12: ...Declaration of conformity 12 en ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ......

Reviews: