Model
L70-17-M04
L80-11-M04
L80-17-M04
L120-11-M04
Type
L70/17C M
L80/11C M
L80/17C M*
L120/11C M
Rated torque [Nm]
70
80
80
120
Output speed [rpm]
17
11
17
11
Limit switch range
36 revolutions
Supply voltage
230 V AC / 50 Hz
Connected load [W]
430
310
470
435
Rated current consumption [A]
1.90
1.40
2.10
1.90
Operating mode
S2 4 min
Degree of protection
IP 44
Min. tube inside diameter [mm]
60
Emission sound pressure level [dB(A)]
≤ 70
*) This tubular drive is not yet available.
What to do if...?
Problem
Cause
Remedy
The roller shutter curtain is raised un-
evenly or not at all.
1.
One or more attachments have
broken off.
2.
Lath has broken off.
Repair system; then reset the limit posi-
tions.
Tubular drive stops arbitrarily; cannot be
restarted in the same direction.
Roller shutter curtain keeps sticking; too
much friction.
Repair system
Tubular drive does not run in the right dir-
ection.
Electrical connection faulty.
Check the electrical connection.