Remote Management (ReMan)
The functions LOCK, UNLOCK and SET CODE are only available 5 minutes after switching
on the mains voltage for the factory-set security code.
The factory-set
security code
is:
1F5340B9
and
must
be changed for further use of ReMan / ReCom. Please ensure you keep
the current security code in a safe place for future reference.
Resetting the security code is only possible with the universal adjustment set (Item no. 4935 000 001 0). To do this, connect the
universal adjustment set to the tubular drive and press the "Delete transmitter" button for 10 seconds. The tubular drive confirms.
The tubular drive supports the following ReMan functions:
•
PING
•
LOCK, UNLOCK, SET CODE
•
QUERY ID, QUERY STATUS
•
ACTION (clicks once when triggered)
These functions are used to secure access to the tubular drive, to address it initially via wireless communication and subsequently
to enable Remote Commissioning functionality.
Information about the individual ReMan functions can be found in the Remote Management Specification of EnOcean GmbH.
Remote Commissioning (ReCom)
The tubular drive supports EnOcean Alliance standardized Remote Commissioning functions. Details on these functions are docu-
mented in the current Remote Commissioning System Specification of the EnOcean Alliance.
Disposal
This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc-
ling or disposal for this product in your country.
The packaging material must be disposed of properly.
Maintenance
These drives are maintenance-free.
Technical data dia. 35
Tubular drive
P5-16
P9-16
Model
N01
Type
C PROF+ EN
Rated torque [Nm]
5
9
Output speed [rpm]
16
16
Limit switch range
64 revolutions
Supply voltage
230 V AC / 50 Hz
Connected load [W]
85
110
Rated current consumption [A]
0.36
0.47
Operating mode
S2 4 min.
Degree of protection
IP 44
Min. tube inside diameter [mm]
37
Frequency
868.3 MHz
Emission sound pressure level [dB(A)]
≤ 70
20 - en
Summary of Contents for enocean P5-16
Page 23: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 23 en ...