Upper point to lower point
There is no shading solution length adjustment with this limit position setting.
Open to the desired upper limit position.
Press the programming button and, within 3 seconds, also press the UP button and
hold the two buttons down.
▻
The tubular drive acknowledges.
Then close to the desired lower limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
and hold the two buttons down.
▻
The tubular drive acknowledges.
►
The limit positions are now set.
Upper stop to lower point
Open to the permanent upper stop.
▻
The tubular drive switches off automatically.
Then close to the desired lower limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
and hold the two buttons down.
▻
The tubular drive acknowledges.
►
The limit positions are now set.
Upper point to lower stop
Open to the desired upper limit position.
Press the programming button and, within 3 seconds, also press the UP button and
hold the two buttons down.
▻
The tubular drive acknowledges.
Then close to the permanent lower stop.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.