background image

BECK-O-TRONIC 4

Version: Centronic

 

 

en

 

Assembly and Operating Instructions

 

 

Door control unit

 

Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.

 

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

 

Summary of Contents for Beck-o-Tronic 4

Page 1: ... Instructions Door control unit Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Page 2: ...d use 6 Explanation of displays and buttons 7 Programming the remote control 8 Deleting transmitters 9 Overwriting the master transmitter 9 Installation 10 Wiring 10 Configuration 11 Maintenance 15 Cleaning 16 Technical data 17 Connecting diagram 18 Declaration of conformity 19 2 ...

Page 3: ...d sensors design with clear display of operating status and error messages optical safety edge connectable without external sensor Please observe these Assembly and Operating Instructions when installing and setting the equipment Caution Denotes a potentially hazardous situation If this is not avoided injuries may result Attention Denotes a potentially hazardous situation If this is not avoided th...

Page 4: ...ance with our instructions particularly the information contained in these Assembly and Operating Instructions Any further processing of the products which does not comply with their intended use is not permitted The end product manufacturer and fitter have to ensure that all the relevant current statutory official and in particular EMC regulations are adhered to during utilisation of our products...

Page 5: ...e system must ensure proper installation instruction of the operator in its use and issue of the CE mark The operator must ensure that the system is only operated in per fect condition and that the safety devices are checked regularly by an expert to ensure they are in full working order A damaged mains connecting cable must be replaced immediately by a qualified electrician When using roller door...

Page 6: ...tion in maintained operation a closing edge safety device is necessary This type of control unit must not be used in potentially explosive areas Other applications uses and modifications are not permitted in order to protect the safety of the users and others since these actions can impair the system s safety and carry the risk of personal injury and property damage The manufacturer does not ac ce...

Page 7: ...E B D F A Radio PRG button B Programming button on the radio re ceiver C Programming button on the transmit ter D LED E Channel selection button F DIP switch DIP ON Defined travel buttons Up Stop Down DIP OFF Pulse sequence Up Stop Down Stop etc 7 ...

Page 8: ...he normal operating status Now close the cover of the control unit again using the four cover screws Programming additional transmitters Note In addition to the master transmitter up to 7 further transmitters can be programmed in the radio receiver Press the programming button C of the master transmitter for 3 seconds The LED D lights up once to confirm Now press the programming button of a new tr...

Page 9: ...ogramming button C on the master transmitter for 3 seconds The LED D lights up once to confirm Press the programming button C on the master transmitter again for 3 seconds The LED D lights up once to confirm Press the programming button C on the master transmitter again for 10 seconds The LED D lights up twice to confirm Æ All transmitters except the master transmitter have now been deleted from t...

Page 10: ...o the wall Wiring Connection of the motor outdoor light advance warning light light barrier ex ternal key operated push button and bottom rail sensor Connect the individual pieces of equipment as shown in the connecting diagram Caution Electrical work may only be carried out by qualified electricians or trained personnel Always disconnect the safety mains plug before connecting the equipment Note ...

Page 11: ...Setting mode Limit position detection and running time monitoring are off The con trol unit does not switch off the power to the tubular drive once a limit position has been reached so the limit position of the door system can be adjusted while it is live This ensures that the door system directly follows the settings of the limit switches To disconnect from the power supply press the STOP button ...

Page 12: ... UP di rection 1 4 7 2 5 8 3 6 ON DIP Closing edge stop mode While the door is closing the light barrier or safety edge is activated The door stops as soon as the safety edge is activated or the light barri er is interrupted No function in the UP direction After encountering an obstruction the door must first clear the obstruction before it can be lowered again 1 4 7 2 5 8 3 6 ON DIP Closing edge ...

Page 13: ...r 1 4 7 2 5 8 3 6 ON DIP General advance warning An advance warning is given for 3 seconds before every door move ment The warning light is only switched off again once a limit position has been reached 1 4 7 2 5 8 3 6 ON DIP Advance warning for automatic closing An advance warning is given for 3 seconds before every automatic clo sure The warning light is only switched off again once a limit posi...

Page 14: ...a delay of 1 minute This time is reduced to 3 seconds by passing the light barrier If the door encounters an obstruc tion automatic closing is aborted after 5 unsuccessful attempts The door must then be moved to the lower limit position using the buttons on the control unit or a hard wired device 1 4 7 2 5 8 3 6 ON DIP Automatic closing with light barrier reduction to 15 seconds The door is closed...

Page 15: ...ty edge is tested during every closing movement Once the pre limit switch is activated the safety edge must be activated within 2 seconds positive testing 1 2 3 Safety edge with 8k2 Ohm terminating resistor without testing 1 2 3 Safety edge with 8k2 Ohm terminating resistor with testing The safety edge is tested during every closing movement Once the pre limit switch is activated the safety edge m...

Page 16: ...Cleaning Only clean the outside of the housing with a suitable cloth Do not use cleaning agents as these may damage the plastic 16 ...

Page 17: ...nly for installation indoors Supply voltage 230 V 50 Hz connection type Y Input power 6 V A Fuse 2 A slow blow Drive switching capacity 1 drive 230 V 50 Hz maximum 260 V A Light switching capacity 230 V 50 Hz maximum 100 W Control voltage 24 V maximum 100 mA Temperature range 10 C to 50 C Radio frequency 868 3 MHz 17 ...

Page 18: ...tact Pre limit switch Light barrier Motor white green brown Outdoor light Warning light e g key switch Emergency stop circuit or anti unrolling device Optical safety edge from FRABA External pre limit switch for the initiation of testing at the pneumatic safety edge contact Keypad Radio PRG Em Stp 18 ...

Page 19: ...Declaration of conformity 19 ...

Page 20: ...4005 630 034 0 30 01 2013 ...