Establishing the program/clear standby
state
1.
To wake up the device, press the "+" or "-" button until the display
switches on automatically.
2.
Press the "+" and "-" buttons simultaneously until the message "LINK"
appears on the display for the program standby state. When the "+" or "-"
button is pressed again, the message "UN-LINK" appears on the display
for the clear standby state.
3.
The control unit is now in the program/clear standby state for 3 minutes.
For subsequent actions, please refer to the corresponding operating instruc-
tions for the device to be programmed.
For information on configuring the heating actuator using the CentralControl,
refer to our homepage:
https://www.becker-antriebe.de/produktuebersicht/hausautomatisierung-
centralcontrol.html
Cancelling the program/clear standby state
Press the "+" and "-" buttons for 5 seconds.
If the heating actuator is at the limit of the radio range, de-
tach the heating actuator and put it into the program/clear
standby state within close range of the CentralControl. You
should then test the heating actuator locally using the Cent-
ralControl to make sure it is working.
There may be a delay of up to 90 seconds before the settings
from the CentralControl arrive at the heating actuator.
Window function
If you open a window and the temperature drops significantly as a result, the
heating actuator closes the valve for 10 minutes to save energy. The message
"WINDOW" appears on the display. You cannot make any settings during this
time.
You can cancel the window function by pressing the "+" button for two
seconds.
14