Remove the connectors with black markings completely before mounting
the required adapter.
1.
Push the appropriate adapter onto the valve and turn it until it audibly en-
gages. Depending on the adapter, it must be secured with the screw and
nut supplied.
2.
Insert the batteries.
3.
Wait until the message "LINK" appears on the display for the installation
standby state, or if "OPEN" appears, press the "+" or "-" button until the
message "LINK" appears on the display. The control unit is now in the
program standby state for 15 minutes. For subsequent actions, please
refer to the corresponding operating instructions for the device to be
programmed.
4.
After linking successfully, the message "OK" appears on the display,
then changes to "OPEN".
5.
Now place the heating actuator on the valve and firmly tighten the
knurled nut.
6.
Now press the "+" and "-" buttons for 5 seconds to allow the heating ac-
tuator to re-adapt to the radiator valve. "ADJ" appears on the display.
11