Operating Instructions
64
FUNCTION (only when the operating device is disconnected,
only for qualified electricians)
EXTERNAL ON/OFF/SWITCH, ALARM SIGNAL ON/OFF
(Processing external signals, processing alarm signals)
1. You have confirmed the RUNNING TIME function. EXTERNAL ON will appear. (EXTER-
NAL ON/ OFF/ SWITCH describes the external control signals. Default setting ist EX-
TERNAL SWITCH)
2. You can select the required setting for the control inputs using the
+/-
button.
3. Confirm your selection by pressing
OK
.
Note
The following dialog window will only be displayed if you have selected DRIVE
CONTROLLER.
4. ALARM SIGNAL ON will appear. (The default setting is ALARM SIGNAL ON.)
5. You can switch the ALARM SIGNAL to ON or OFF using the
+/-
button. Confirm by
pressing
OK
.
6. The function ALARM SIGNAL ON/OFF has now been set.
7.
Please read on for further programming options using the FUNCTION menu.
EXTERNAL ON
EXTERNAL OFF
ALARM SIGNAL
ON
EXTERNAL
SWITCH
Drive
controller ?
ALARM SIGNAL
OFF