12
3. Close the door.
4. Switch the “Power” switch on.
5. Hold the “Delay” button down and then press the “Programme”
button for 5 seconds. The buzzer rings once and H appears flashing
on the digital display. (Factory settings is H4.)
To change the settings:
1. Press the “Delay” button. Each time this button is pressed, the set
value increases by one level; when the value of H7 has been reached,
the display jumps back to H0 (off).
2. Press the “Programme” button. The chosen settings has now been
stored.
Contact your local water authority for information on the hardness of
water supplied.
Water hardness table
Water hardness
Mmol/l
Set value on
the machine
Clark
Range
0-8
soft
0-1.1
H0
9-10
soft
1.2-1.4
H1
11-12
medium
1.5-1.8
H2
13-15
medium
1.9-2.1
H3
16-20
medium
2.2-2.9
H4
21-26
hard
3.0-3.7
H5
27-38
hard
3.8-5.4
H6
39-62
hard
5.5-8.9
H7