OPTIONAL EQUIPMENT 

 
 
 
 

A standard automatic, single station escapement unit can be 
supplied for mounting at an assembly station.  Four tapped #10- 
32 mounting holes are provided.  Units with multiple outlet 
escapements can be quoted on request. 
 
The 

Automatic Escapement

 is mounted below the spring feeder 

and will dispense one (1) spring when activated by an air signal. 
The factory supplies this unit with a restricting fitting installed 
on the air cylinder.  If this fitting is removed, the air signal provided 
by the customer must be controlled air.  Full line flow/pressure 
will damage the unit. 
 
 
 
 
 

 
 

 

 

 

 

 

 

An 

Automatic Escapement Timer

 (PN: 69000-775) 

may be used to automatically actuate the escapement 
at  a  pre-determined  time  interval.  The  time  interval 
may  be  varied  allowing  the  customer  to  dynamically 
adjust their spring dispensation rate.  
 
 
 
 
 

 
 
 
The automatic escapement can also be actuated via an optional 

Air Operated Foot-Pedal 

(not 

shown). This unit allows the user of an auto escapement to manually dispense a spring as desired 
by stepping on the foot-pedal. Depressing the pedal allows air to pass though to the escapement 
and thus actuate the solenoid.  
 
 
 
 
 

Summary of Contents for BECMATIC 550

Page 1: ... Sodus NY 14551 315 483 6923 TEL 315 483 6656 FAX Email sales becherair com LAST UPDATED 07 MAY 2015 BECMATIC MODELS 550 600 602 652 OWNER S MANUAL BECMATIC SPRING FEEDERS Spring No Revision MODEL ID SERIAL FEED RATE DATE ...

Page 2: ...rn Information Page 3 Setup Page 4 Installation of Feed Tube s Page 4 Mounting Page 5 Operation Page 10 Optional Equipment Page 11 Troubleshooting Page 13 Preventative Maintenance Page 14 Parts List Page 16 Set up Example Page 17 ...

Page 3: ... volume are preset at the factory and the case has been sealed to maintain proper airflow Disassembly or modifications to this unit may impair operation and or void warranty RETURN INFORMATION Call Factory for return authorization Carefully pack unit to avoid damage in shipment Insure for full value of the unit Include detailed description of problem name and phone number of the contact person a q...

Page 4: ...ravity feed of the springs through the feed tube Feed tube length should be kept as short as possible to eliminate excess backpressure 36 maximum INSTALLATION OF FEED TUBE S The feed tube is inserted into the outlet nozzle on the front of the feeder The lock collar should be adjusted to provide a secure grasp on the feed tube Over tightening the lock collar will result in damage to the nozzle and ...

Page 5: ...pacity Vol 5 qt 5 ltr Electrical 115 VAC 1 5A 230VAC 1A Air 80 p s i 5 6 kg cc2 Air Supply 250 min 6 mm min CLEAN AIR 110V AC 80 P S I 80 LBS P S I CLEAN AIR 115VAC 60HZ GROUNDED POWER SUPPLY 230VAC OPTIONAL ESCAPEMENTS SPRING TO DIVISION OF C ASSOCIATES LLC MODEL NO SERIAL NO WWW BECHERAIR COM SODUS NY 315 483 6923 ...

Page 6: ...qt 1 4 ltr Electrical 115 VAC 1 5A 230VAC 1A Air 80 p s i 5 6 kg cc2 Air Supply 375 min 10 mm min CLEAN AIR 110V AC 80 P S I 6 75 16 00 9 75 18 00 OPTIONAL 115VAC 60HZ GROUNDED POWER SUPPLY 230VAC CLEAN AIR 80 LBS P S I ESCAPEMENTS SPRING TO DIVISION OF C ASSOCIATES LLC MODEL NO SERIAL NO WWW BECHERAIR COM SODUS NY 315 483 6923 11 00 ...

Page 7: ...Electrical 115 VAC 1 5A 230VAC 1A Air 80 p s i 5 6 kg cc2 Air Supply 375 min 10 mm min CLEAN AIR 110V AC 80 P S I 6 75 16 00 9 75 11 00 18 00 MODEL 602 ONLY 80 LBS P S I CLEAN AIR 115VAC 60HZ GROUNDED POWER SUPPLY 230VAC OPTIONAL ESCAPEMENTS TO SPRING 11 64 DIVISION OF C ASSOCIATES LLC MODEL NO SERIAL NO WWW BECHERAIR COM SODUS NY 315 483 6923 ...

Page 8: ...Capacity Vol 3 qt 2 8 ltr Electrical 115 VAC 1 5A 230VAC 1A Air 80 p s i 5 6 kg cc2 Air Supply 375 min 10 mm min 110V AC CLEAN AIR 90 P S I ESCAPEMENTS TO SPRING 230VAC OPTIONAL 115VAC 60HZ SUPPLY POWER GROUNDED 90 LBS P S I CLEAN AIR DIVISION OF C ASSOCIATES LLC MODEL NO SERIAL NO WWW BECHERAIR COM SODUS NY 315 483 6923 ...

Page 9: ...9 MOUNTING SPECIFICATIONS AUTOMATIC ESCAPEMENT ...

Page 10: ...ar chamber of the spring feeder detangler It is recommended that the quantity be kept to no more than is necessary to prevent excessive spinning of springs which may result in hooked or damaged parts Figure 3 Severely tangled or hooked springs should be removed from the reservoir prior to adding new parts Springs should be stored in closed containers to avoid contamination and damage Springs shoul...

Page 11: ...is removed the air signal provided by the customer must be controlled air Full line flow pressure will damage the unit An Automatic Escapement Timer PN 69000 775 may be used to automatically actuate the escapement at a pre determined time interval The time interval may be varied allowing the customer to dynamically adjust their spring dispensation rate The automatic escapement can also be actuated...

Page 12: ...g one spring at a time into position Units are tooled for specific spring sizes up to 250 inch diameter and 500 inch long The Bench type Escapement provides for dispensing of one spring at a time for manual pickup and placement Available for spring sizes 250 to 500 inch diameter ...

Page 13: ...door latch replace gasket Unit runs will not feed springs Window s leaking Replace windows Supply reservoir over filled Remove springs to restore operating level Unit runs feed rate inadequate Insufficient volume in supply reservoir Add springs to restore operating level Feed tube kinked worn or obstructed Replace feed tube Springs have been magnetized Remove and degauss springs Springs dirty or o...

Page 14: ...licable Once year Check paddlewheel inserts for wear Insert should protrude from paddlewheel body by at least 0 75 inches New insert extends 0 84 inches If paddlewheel inserts are excessively worn feeder may have difficulty keeping up with required feed rate See parts list Once year Check door gasket for damage or wear which may cause air leaks at door feeder interface Replace if necessary See par...

Page 15: ... over torque as this could induce twist into assembly causing it to bind when actuated Tighten screws on each end of the slide rods to a snug condition then actuate the escapement by hand to verify freedom of movement throughout the actuation range Complete the tightening in a rotational fashion until all screws are tight After all hardware is tight verify freedom of movement throughout actuation ...

Page 16: ...ASKET 69000 490 69000 490 WINDOW 4 69000 616 69000 616 MOTOR 69000 439 01 69000 439 02 MODEL 652 115 VOLT 230 VOLT AIR VALVE SM 2 69000 406 69000 406 01 AIR VALVE LG 69000 405 69000 405 01 TIMER 69000 404 05 69000 404 06 ON OFF SWITCH 69000 403 69000 403 MOTOR 69000 439 01 69000 439 02 PUSHER CYLINDER 69000 411 69000 411 CYLINDER CLEVIS 69000 496 69000 496 PADDLE WHEEL 5 69000 694 69000 694 PADDLE...

Page 17: ...17 ...