BeautyRelax BR-720 User Manual Download Page 5

Ultrasound cavitation system 3in1 BeautyRelax BR-720 

User Guide 

 

 

 
 
 
 

 
 
 
 
 

abdome

calf 

buttocks 

Infrared light function - application process

 

For  more  effective  body  shaping  recommend  during  ultrasonic  cavitation  can  also  activate  the 
infrared  light.  Along  the  perimeter  of  the  applicator head  units  are  built  in  4  IR  emitters.  Infrared 
rays  penetrate  into  the  body  in  the  wavelength  range  of  8  to  12nm.  The  infrared  radiation  in 
comparison  to  other  sources  of  heat  better  ability  to  penetrate  deeper  into  the  subcutaneous 
tissue. Infrared heat is strongly supported by circulation. The body is then able to quickly get rid of 
harmful substances and waste products. Contributes to the overall regeneration and recovery of the 
body. 
 
To use infrared light functions: 
1. After you connect the device to the mains cable, press INFRARED button. 
2.  The  function  is  activated  button  glows  INFRARED  and  4  LEDs  around  the  perimeter  of  the 
applicator head. 
3. During the movement across the skin will feel warmth. 
4.  Functions  of  infrared  light  turns  off  automatically  after  10  minutes  or  can  be  switched  off  by 
yourself pressing INFRARED button (LEDs and button is off). 

Ultrasound cavitation system 3in1 BeautyRelax BR-720 

User Guide 

 

10 

 

  
 Please take the time following instructions in order to use the device correctly and safely.  
 
 
 
 
Electrostimulator use is prohibited, unless simultaneously using these devices: 
 
1. Medical electronic devices (eg. A pacemaker). 
2. Such medical electronic devices that support vital functions  
(eg. An artificial heart, lungs, liver, etc.). 
3. Other medical devices (eg. Electrocardiograph). 
 

 

 
 
If you suffer from the following health symptoms, contact your doctor or medical help: 
 
1. acute problems 
2. heart problems 
3. the High fever 
4. pregnancy 
5. malignant tumors 
6. persistent low or high blood pressure 
7. infected wound or similar serious injury 
8. allergic skin problems 
9. submission to medical diagnostic therapy 
10. inconvenient continuous muscle pain due to their excessive overload 

 

If you are affected by any of the above, it is forbidden to use the 

electrostimulator. 

 

Observe the following guidelines: 
 

 

1.

 

It  is  prohibited  to  place  the  electrode  in  the  area  of  the  heart,  neck,  head,  into  the  genital 

 

area. Do not use electrodes to areas which suffer from skin diseases or scrapes. 

2.

 

The instrument must not be used in combination with other medical devices. Before using do 

 

not use creams or sprays. This could cause damage to the skin. 

3.

 

The device use according to a strict instructions in this manual. The device must not be used 

 

for purposes other than combat muscle pain, tension and muscle strengthening. 

4.

 

Electrodes  that  are  part  of  the  package.  They  are  designed  exclusively  to  connect  to  the 

 

electrostimulator device. 

5.  

The  apparatus  themselves  not  repair,  disassemble,  remove  any  of  its  components.  The 

 

guarantee would then lose its validity and possibly caused damage to health or property we 

 

would not take no responsibility. 

6.  

Without previous careful study of this manual must not use the device. 

 

Electrostimulator - application process

 

Dangerous 

Warning 

Summary of Contents for BR-720

Page 1: ...t be treated Body parts which is possible to treat recommended treatment time Performance devices and specifications technology Features and specifications Technical parameters Device and device parts...

Page 2: ...ion instrument skin disease persons suffering from fatigue syndrome persons who require constant supervision the unit may only be used after prior consultation with a doctor Do not attempt to disassem...

Page 3: ...rces of heat better ability to penetrate deeper into the subcutaneous tissue Infrared heat is strongly supported by circulation The body is then able to quickly get rid of harmful substances and waste...

Page 4: ...es will turn on pressing SONIC One press switches on the mode LOW low it will light the LED diode at the letter L A second press switches on the mode HIGH high level it will light the LED diode at the...

Page 5: ...emaker 2 Such medical electronic devices that support vital functions eg An artificial heart lungs liver etc 3 Other medical devices eg Electrocardiograph If you suffer from the following health sympt...

Page 6: ...is is very important for the correct transmission of pulses through the skin 2 Each electrode plug to the flat connector 3 Electrodes stick to the body part that you want to treat 4 Cable electrodes c...

Page 7: ...v m a slazen m vod m T den po o et en ultrazvukem byste se m li vyvarovat konzumaci alkoholu kofeinu nikotinu t k ch a mastn ch j del V echny tyto faktory zat uj va e j tra kter jsou ji tak zat ena fi...

Page 8: ...ify the diet and increased fluid intake Treatment ultrasonic cavitation can safely undergo after 7 10 days We do not recommend treatment more than two batches simultaneously If the caregiver of games...

Reviews: