Beamz 151.276 Instruction Manual Download Page 3

 

UNPACKING INSTRUCTION   

CAUTION!

 Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are 

present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if 
any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing 
materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original 
factory box and packing. 
 
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The 
arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. 

 

POWERSUPPLY 

On the label on the backside of the controller is indicated on this type of power supply must be connected. Check that the mains 
voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The controller must 
also be directly connected to the mains and may be used. No dimmer or adjustable power supply. 
 
 

INSTALLATION 

 

 

 

Attention: 

 

The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight 
for 1 hour without any harming deformation. 

 

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. 
This secondary safety attachment must be constructed in a way that no part of the installation can fall down 
if the main attachment fails. 

 

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging 
and servicing. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert before taking into operation for the first time and after changes before taking into operation another 
time. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by a 
skilled person once a year. 

 

The fixture should be installed in the position where persons cannot reach and where persons may walk by 
or be seated. 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION:     Please consider the respective national norms 

during the installation! The installation must only be 
carried out by an authorized employee or dealers! 

CAUTION:     When installing the device, make sure there is no 

highly in inflammable material (decoration articles, 
etc.) in between a distance of min 0.5 meter. 

Summary of Contents for 151.276

Page 1: ...FlatPAR 7x15W RGBAW DMX IR Ref nr 151 276 INSTRUCTION MANUAL MANUEL D INSTRUCTIONS V1 1...

Page 2: ...russ system with clamps Make sure nobody stands in the mounting area Mount the effect at least 50cm away from inflammable material and leave at least 1 meter space on every side to ensure sufficient c...

Page 3: ...table power supply INSTALLATION Attention The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The i...

Page 4: ...If you use a controller with 5 pin DMX connection you will need to use a 5 pin to 3 pin adapter At the last fixture the DMX cable has to be terminated Solder a 120 Ohm resistor between signal and sig...

Page 5: ...cumulation of dirt on the unit s optics Make sure the area below the installation place is free from unwanted persons during servicing Housings fixations and installations spots ceiling truss suspensi...

Page 6: ...e trouver sous l appareil Il doit tre mont 50 cm au moins de tout mat riau inflammable et un m tre au moins de toute surface pour garantir son bon refroidissement Cet appareil contient des LEDs de gra...

Page 7: ...upporter 10 fois le poids de l appareil pendant une heure sans aucune d formation L installation doit toujours tre assur e par un second syst me de fixation par exemple un filet ou une lingue Ce secon...

Page 8: ...vous devez utiliser un adaptateur 5 p les 3 p les Sur le dernier appareil le cordon DMX doit tre termin par un bouchon Soudez une r sistance 120 ohms entre signal et signal sur une prise XLR 3 p les e...

Page 9: ...rtante de salissures sur les optiques Assurez vous que personne ne se trouve sous l emplacement d installation pendant le nettoyage Les bo tiers fixations et l ments d installation plafond structures...

Page 10: ...witching 201 255 Sound colour fading 9 Speed 000 255 Auto Sound Mode from Slow to fast MANUAL SETTING MODE MANUEL R GLAGES Mode Programming Steps Description Auto Au 1 Switching 1 Au 2 Switching 2 Au...

Page 11: ...darf am Ende seiner Lebensdauer nicht ber den normalen Haushaltsabfall entsorgt werden sondern muss an einem sammelpunkt f r das Recycling abgegeben werden Hiermit leisten Sie einen wichtigen Beitrag...

Page 12: ...number 153 276 Product Description FlatPAR 7x15W RGBAW DMX IR Trade Name BEAMZ Regulatory Requirement EN 60598 1 2 17 EN 61000 3 2 3 3 EN 55015 EN 61547 The product meets the requirements stated in Di...