UNPACKING INSTRUCTION   

CAUTION!

 Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are 

present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if 
any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing 
materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original 
factory box and packing. 
 
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The 
arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. 

 

POWERSUPPLY 

On the label on the backside of the controller is indicated on this type of power supply must be connected. Check that the mains 
voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The controller must 
also be directly connected to the mains and may be used. No dimmer or adjustable power supply. 
 
 

INSTALLATION 

 

 

 

Attention: 

 

The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight 
for 1 hour without any harming deformation. 

 

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. 
This secondary safety attachment must be constructed in a way that no part of the installation can fall down 
if the main attachment fails. 

 

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging 
and servicing. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert before taking into operation for the first time and after changes before taking into operation another 
time. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by a 
skilled person once a year. 

 

The fixture should be installed in the position where persons cannot reach and where persons may walk by 
or be seated. 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION:     Please consider the respective national norms 

during the installation! The installation must only be 
carried out by an authorized employee or dealers! 

CAUTION:     When installing the device, make sure there is no 

highly in inflammable material (decoration articles, 
etc.) in between a distance of min 0.5 meter. 

Summary of Contents for 151.155

Page 1: ...LED Par36 DMX 9x1W RGB Ref nr 151 155 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS V1 0...

Page 2: ...russ system with clamps Make sure nobody stands in the mounting area Mount the effect at least 50cm away from inflammable material and leave at least 1 meter space on every side to ensure sufficient c...

Page 3: ...table power supply INSTALLATION Attention The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The i...

Page 4: ...chain FIXTURE CLEANING The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in wh...

Page 5: ...ebruik en direct na gebruik Om ongevallen in bedrijven te voorkomen moet rekening worden gehouden met de daarvoor geldende richtlijnen en moeten de aanwijzingen waarschuwingen worden gevolgd Zorg voor...

Page 6: ...overeenkomt bij alle andere netspanningen dan aangegeven kan de controller onherstelbaar worden beschadigd Tevens moet de controller direct op de netspanning worden aangesloten en mag g n dimmer of r...

Page 7: ...t laatste apparaat in de lijn ONDERHOUD Het schoonmaken van inwendige en uitwendige optische lenzen en of spiegels moet regelmatig worden uitgevoerd om de lichtopbrengst te optimaliseren Schoonmaken f...

Page 8: ...sen system mit Haken W hrend der Montage darf sich niemand im Bereich darunter aufhalten Das Ger t muss mindestens 50cm von brennbaren Materialien entfernt angebracht werden Lassen Sie einen Mindestab...

Page 9: ...al das Eigengewicht 1 Stunde lang ohne Spuren von Verformung tragen k nnen Die Anlage muss immer mit einer zweiten Sicherheitsvorrichtung z B einem geeigneten Fallnetz abgesichert werden Die zweite Si...

Page 10: ...ARTUNG Der inneren und u eren optischen Linsen und oder Spiegel m ssen regelm ig gereinigt werden um die Lichtleistung zu optimieren Die H ufigkeit der Reinigung h ngt von der Umgebung in der das feuc...

Page 11: ...nta en un techo Utilice un sistema de truss con ganchos Aseg rese de que nadie permanece en el rea de montaje Monte el efecto a una distancia de al menos 50cm de materiales inflamables y deje un espac...

Page 12: ...zado No en ninguna fuente de alimentaci n o dimmer ajustable INSTALACI N Atenci n La instalaci n del aparato debe ser de una manera que pueda soportar 10 veces su peso durante 1 hora sin sufrir deform...

Page 13: ...La limpieza de lentes y o espejos internos y externos debe ser llevada a cabo peri dicamente para optimizar la salida de luz La frecuencia de limpieza depende del entorno en el que funcione el aparat...

Page 14: ...se trouver sous l appareil Il doit tre mont 50 cm au moins de tout mat riau inflammable et un m tre au moins de toute surface pour garantir son bon refroidissement Cet appareil contient des LEDs de gr...

Page 15: ...er 10 fois le poids de l appareil pendant une heure sans aucune d formation L installation doit toujours tre assur e par un second syst me de fixation par exemple un filet ou une lingue Ce second syst...

Page 16: ...branchez la la sortie DMX du dernier appareil de la cha ne NETTOYAGE Le nettoyage des lentilles optiques internes et externes et ou miroirs doit tre fait r guli rement pour un rendu lumineux optimal L...

Page 17: ...de 075 119 Sound active mode 1 120 164 Sound active mode 2 165 209 Sound active mode 3 210 255 Sound active mode 4 TECHNICAL SPECIFICATION TECNISCHE SPECIFICATIE TECHNISCHE DATEN ESPECIFICACIONES T CN...

Page 18: ...DMX 9x1W RGB Trade Name BEAMZ Regulatory Requirement EN 60598 1 2004 A1 2006 EN 60598 2 17 1989 A2 1991 EN 55014 1 2006 EN 55014 2 1997 A1 2001 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 The...

Page 19: ...Specifications and design are subject to change without prior notice www tronios com Copyright 2015 by TRONIOS the Netherlands...