background image

- 5 - 

 

OPERATION INSTRUCTIONS 

Operation instructions for control panel 

 

 

 

 

BUTTON FUNCTION 

Mode 

Select a function of mode 

Enter 

Confirm a function of mode and save 

Up 

Select increasing advancement in the value 

Down 

Select decreasing advancement in the value 

 

The Control Panel shows the current state of the unit, it is used to select the operating mode ,as well 
as the sub-features. For a detailed layout of the control panel functions, please see the “menu map” 
section below. 
 

Functions for control panel 

Menu 

Program 

Run Speed (P) 

Strobe Speed (F) 

Description 

001 

 

000 

No Strobe 

 

001 – 099 

Strobe 

Slow->Fast 

 

100 

Sound-active strobe 

Red (static) 

002 Green 

(static) 

003 Blue 

(static) 

004 Yellow 

(static) 

005 Magenta 

(static) 

006 Cyan 

(static) 

007 White 

(static) 

008 

000 

Only sound-active 

 

001 – 009 

Run Speed 
Slow->Fast 

 

100 

No Delay 

Auto/Sound Mode 1 

009 Auto/Sound 

Mode 

010 Auto/Sound 

Mode 

011 Auto/Sound 

Mode 

012 

 

Auto/Sound Mode 5 

013 Auto/Sound 

Mode 

014 Auto/Sound 

Mode 

015 Auto/Sound 

Mode 

016 Auto/Sound 

Mode 

017 Auto/Sound 

Mode 

10 

018 Auto/Sound 

Mode 

11 

019 Auto/Sound 

Mode 

12 

020 Auto/Sound 

Mode 

13 

021 Auto/Sound 

Mode 

14 

022 Auto/Sound 

Mode 

15 

023 Auto/Sound 

Mode 

16 

024 Color 

Fade 

001 - 485 

 

 

DMX address 

 
 

 

 

 

Summary of Contents for 150.666

Page 1: ...Ref Nr 150 666 LCP 48 LED COLOR PANEL 48X 1W RGB MANUAL ...

Page 2: ...e contents of the carton 3 Safety Instructions 3 Product Overview 4 Functions Introductions 4 Main Functions 4 Operation Instructions 5 Functions for control panel 5 Master Slave mode 6 Master Slave connection 6 Sound Active Mode 6 Automatic Mode 6 Controlled by DMX512 7 DMX Value Functions 8 27 Channel mode 8 15 Channel mode 9 9 Channel mode 9 6 Channel mode 9 3 Channel mode 10 Maintenance 10 Spe...

Page 3: ...ts in transportation Never carry the product from the power cord or any moving part Always use the hanging mounting bracket or the handles The product is used in door only Never pull or tug on the cord and change it for another one stop using it when it is damaged or becomes hot Stop using the product once there is sparks when connecting with the power plug Can not operate product with wet hands a...

Page 4: ...rol panel 7 Power input 8 Power output 9 Hanging bracket 10 LEDs FUNCTIONS INTRODUCTIONS Main Functions 3 6 9 15 27 DMX channels Automatic sound active and master slave mode Built in 24 actions individual control of RGB LEDs running and strobe speed can be adjusted With static colors strobe color mixing chasing and fade effect ...

Page 5: ...Menu Program Run Speed P Strobe Speed F Description A 001 000 No Strobe 001 099 Strobe Slow Fast 100 Sound active strobe Red static 002 Green static 003 Blue static 004 Yellow static 005 Magenta static 006 Cyan static 007 White static 008 000 Only sound active 001 009 Run Speed Slow Fast 100 No Delay Auto Sound Mode 1 009 Auto Sound Mode 2 010 Auto Sound Mode 3 011 Auto Sound Mode 4 012 Auto Sound...

Page 6: ...ction Sound Active Mode It is sound active with music without sound controlling when running speed is zero it stops Running when strobe speed is zero no strobe when strobe speed is one hundred strobe by sound Automatic Mode Turn off the sound sensitivity adjustment knob or music the product displays current actions automatically Master Slave Slave Continue ...

Page 7: ... 7 Controlled by DMX512 Follow below picture and power on all connected at the same time The products will be controlled once the address is set up DMX input DMX output Continue ...

Page 8: ... color only 4 000 255 Red Section 1 5 000 255 Green 6 000 255 Blue 7 000 255 Red Section 2 8 000 255 Green 9 000 255 Blue 10 000 255 Red Section 3 11 000 255 Green 12 000 255 Blue 13 000 255 Red Section 4 14 000 255 Green 15 000 255 Blue 16 000 255 Red Section 5 17 000 255 Green 18 000 255 Blue 19 000 255 Red Section 6 20 000 255 Green 21 000 255 Blue 22 000 255 Red Section 7 23 000 255 Green 24 0...

Page 9: ...5 Blue 9 Channel mode CHANNEL VALUE FUNCTION SECTION NOTES 1 040 059 9 Channel Mode Set this channel between these values for this mode 2 This Channel is not used for this mode 3 000 002 Strobe No Strobe 003 249 Slow Fast 250 255 Sound Active static color only 4 000 255 Red Section 1 5 000 255 Green 6 000 255 Blue 7 000 255 Red Section 2 8 000 255 Green 9 000 255 Blue 6 Channel mode CHANNEL VALUE ...

Page 10: ...ould be cleaned periodically to ensure the optimum performance the smudginess can decrease the life of light and the output of light is affected by the dust which can make the machine overheating In general make the maintenance at least two times a month Be sure to power off the unit before cleaning Do not clean until the unit recovers normal temperature since high temperature for using use the le...

Page 11: ...cription Beamz LCP 48 LED Color Panel 48x 1W RGB Regulatory Requirement EN 60598 1 2 17 2009 EN 62031 2008 EN 61347 2 13 2007 EN 62479 2010 EN 55015 2006 A2 2009 EN61547 2009 The product meets the requirements stated in the above mentioned Standards This certificate does not cover the aspects that may be relevant such as performance and fitness for purpose Almelo 10 03 2012 Signature ...

Page 12: ...Specifications and design are subject to change without prior notice www tronios com Copyright 2013 by TRONIOS the Netherlands ...

Reviews: