IridiTRAK Installation & User Manual
MT (Mobile Terminated) Remote Commands Format
The BEAM IridiTRAK is designed to handle remote configuration and control
commands via SBD/email.
The remote configuration options allow you to control many settings. This enables
you to make changes to setting durations, clearing alerts, sending acknowledgement
and remote polling.
To configure your RST remotely you will need to know its IMEI and Supervisor PIN.
The basic format for remote commands are as follows.
LTK <response location> @<supervisor pin> <command> <command>...
For example:
LTK SBD @3170 A
This would return the status information via
SBD.
Remote Command Listing
Function
Query Command
Update Command
Equation Processing
71
71y – Turn on
71n – Turn off
Status
A
N/A
Position Reports Time
731
731[value]
Value: Numeric value no
greater then 64bits.
Emergency Message
Time
732
732[value]
Value: Numeric value no
greater then 64bits.
Time before going to
Sleep
733
733[value]
Value: Numeric value no
greater then 64bits.
Server Acknowledgement N/A
723y
Note: Use NOREP in
<response location>
Turn OFF Emergency
N/A
725y
Note: Use NOREP in
<response location>
Remote Polling
N/A
726y
Note: Use NOREP in
<response location>
Page 30 of 46