Look foward to it.
11
Alerts / Errors
Datenblatt
Alert Cause Remedy
LED 11 on handle flashing and a
Hot water module empty
Refill hot water module
“short interval” beep sounds
and check the bottle is
positioned correctly
Distilled water in the
Empty the hot water module and refill
hot water module
with tap water
LED 3 on “Steam” control button
Water reservoir for steam
Fill water reservoir with clean
flashing and a “long interval”
production empty
tap water
beep sounds
Filter bowl reached max. fill level
Empty filter bowl and fill with
fresh water up to MIN. marking
LEDs on both control buttons
Appliance has limescale
Perform descaling, see page 9
flashing in sequence
LED 1 on “Steam” control button
Appliance heating up
Stops flashing after approx 3 minutes,
flashing
appliance is then ready to use.
During work the flashing merely advises you
that heating is correct
LEDs 4 to 6 on “Suction” control
Suction not yet activated
Press the “Suction” control button once
button flashing
briefly with the suction hose inserted
Error Cause Remedy
Suction getting weaker
Mesh filter dirty
Clean mesh filter, see page 8
Foreign body in hose
Check suction hose for foreign
bodies and remove these
Hepa filter and black strainer
Check filter, clean and replace if
dirty or worn out
needed
Suction runs briefly, but then
Too much water in the filter bowl,
Empty filter bowl and refill with
stops
max. fill level reached
fresh water up to the MIN marking
Separator plate not fully or
Push the separator plate in the filter
incorrectly positioned
bowl downwards, or correct position
Sensors and filter bowl dirty
Clean filter bowl with built-in
parts
Poor steam performance
Limescale in hose
Descale hose, see page 10
No steam coming out
Child lock activated
Release child lock on handle
Hot water module activated,
Press button 9 on the handle
LED 11 lit or flashing
briefly to deactivate the hot water module
again and then press the steam lever
Steam very wet
Hot water module activated
Press button 9 on the handle briefly to
deactivate the hot water module again
Too much or too little steam
Steam flow control knob
Set the right steam flow using
in wrong position
the control kno
Hot water module not working
Not activated on handle
Press button 9 on the handle
for 3 seconds until LED 11 lit
Hot water module not fully
Remove hot water module
engaged
from appliance and then reinsert
Limescale in hot water pump
Perform hot water descaling,
see page 10
No function on handle
Contact problem
Check whether steam suction hose is
correctly inserted into the connector