74
4233 5000 13
8.6 Purge plug identification/changeout dMED 25 & 35
•
Remove dryer front panel.
•
Remove purge plug securing screw from the upper valve block.
•
Remove purge plug.
•
Replace with appropriate purge plug according to inlet pressure.
Refer to table above.
•
Grease purge plug O-ring to ensure ease of fit
1. Securing screw
2. Purge plug
Ensure shutdown and start up procedures are followed prior to carrying out any purge
plug changeout
Purge Plug Identification
Model
Operating Pressure (barg)
4
5
6
7
8
9
10
11
12
13
14
15
16
dMED025
PPK020
PPK018
PPK016
PPK015
PPK014
PPK014
PPK013
PPK013
PPK013
PPK012
PPK012
PPK012
PPK012
dMED035
PPK028
PPK023
PPK021
PPK020
PPK018
PPK018
PPK016
PPK015
PPK015
PPK014
PPK014
PPK014
PPK014