75.5366.07 UL MAGLOCKS 20171130
Page 3 of 4
75.5366.07 UL MAGLOCKS 20171130
Page 3 of 4
Page 2 of 2
75.5366.02 20140401
5 Installation - Mechanical & Electrical
LOCK ST
ATUS SWITCH (SPDT)
POWER
SUPPL
Y
+ -
POWER
SELECT
OR
JUMPER
LED
MAG BOND SENSOR
MAGNET
TIMER (0-90 SEC)
TYPICAL INSTALLATION
NOTE: DO NOT over-tighten the armature plate. The rubber washer is designed to allow the armature
plate to automatically adjust position for best mating position between the lock and armature plate.
DOOR FRAME
ARMATURE PLATE
MAGNET
ANGLE
BRACKET
MOUNTING
PLATE
MOUNTING
PLATE
STRINGER
HOLE FOR
GUIDE PIN
HOLE FOR NUT
RUBBER WASHER
STEEL WASHER
ARMATURE PLATE
SCREW M8 (35MM)
GUIDE PIN
DOOR
NUT
SPACER
WASHER
ARMATURE
PLATE
DOOR
NUT
DOOR FRAME
DOOR FRAME
DOOR
ARMATURE PLATE
ARMATURE PLATE
MAGNET
MAGNET
DOOR
DOOR
MOUNTING
PLATE
CAUTION: Observe proper
circuit board orientation!
NOTE: The product must be powered from a UL listed, regulated, power limited, power supply.
NOTE: If power switch is not wired between DC source voltage and magnet,
it will take a longer time to de-energize the magnet simulating residual magnetism.
1. 12 VDC INPUT
A. Required power 0.5A (Max).
B. Connect ground (-) lead from a 12 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 12 VDC power source to Terminal 1.
D. Check jumper for 12 VDC operation.
2. 24 VDC INPUT
A. Required power 0.25A (Max).
B. Connect ground (-) lead from a 24 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 24 VDC power source to Terminal 1.
D. Check jumper for 24 VDC operation.
3. CONTACTS
1. Relay dry contacts are rated 1A at 24 VDC for safe operation, DO NOT exceed this
rating.
2. If a NO switch is required, connect the wires from the system to Terminal 4 & Terminal 3.
3. If a NC switch is required, connect the wires from the system to Terminal 4 & Terminal 5.
DS VERSION
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
75.5366.07 UL MAGLOCKS 20171130
Page 3 of 4
Circuit Board for 600 lb Maglocks
NOTE: Terminals ratings: 12~24AWG
Circuit Board for 1200 lb Maglocks
7 Installation
–
Electrical
CAUTION! Observe
proper circuit board
orientation!
+ -
G
1 2 3 4 5
+ - NO C NC
12VDC
24VDC
POWER
SELECTOR
JUMPER
0 - 90 SEC.
RELOCK TIMER
POWER
SUPPLY
+ -
LOCK STATUS RELAY (SPDT)
G
R B G
R
G
B
W
1 2 3 4 5
+ - NO C NC
12VDC
24VDC
POWER
SELECTOR
JUMPER
0 - 90 SEC.
RELOCK TIMER
POWER
SUPPLY
LOCK STATUS RELAY (SPDT)
Align the black, plastic piece of the
armature plate with the cover plate (i.e.
magnet must line up with the switch).
6 Armature Plate Installation
1
PCB
2
MAGNETIC LOCK
sw
+
-
NC
RED
GREEN
BLACK
LIGHT
COM
REED SWITCH
ON
DOOR STATUS SENSOR SWITCH*
* Switch changes state when door is open
NO
1
PCB
2
MAGNETIC LOCK
NC
RED
GREEN
BLACK
LIGHT
COM
REED SWITCH
ON
DOOR STATUS SENSOR SWITCH*
* Switch changes state when door is open
NO
Hole For Guide Pin
Hole For Nut
Rubber Washer
Steel Washer
Armature Plate
Nut
Spacer
Door
Screw M8 35mm
Guide Pin
The product must be powered from a UL-listed, regulated, power-limited, power supply.
If power switch is not wired between DC source v) and magnet, it will take a
longer time to de-energize the magnet simulating residual magnetism.
12 VDC INPUT
- Required power: See Specifications on page 2.
- Connect positive (+) lead from a 12 VDC power source to Terminal 1.
- Connect negative (-) lead from a 12 VDC power source to Terminal 2.
- Check jumper for 12 VDC operation.
24 VDC INPUT
- Required power: See Specifications on page 2.
- Connect positive (+) lead from a 24 VDC power source to Terminal 1.
- Connect negative (-) lead from a 24 VDC power source to Terminal 2.
- Check jumper for 24 VDC operation.
(600 lb)
(1200 lb)
G
R B G
R
G
B
W
1 2 3 4 5
+ - NO C NC
12VDC
24VDC
POWER
SELECTOR
JUMPER
0 - 90 SEC.
RELOCK TIMER
POWER
SUPPLY
LOCK STATUS RELAY (SPDT)
+ -
G
1 2 3 4 5
+ - NO C NC
12VDC
24VDC
POWER
SELECTOR
JUMPER
0 - 90 SEC.
RELOCK TIMER
POWER
SUPPLY
+ -
LOCK STATUS RELAY (SPDT)
POWER