BEA UL MAGLOCKS 600LB User Manual Download Page 2

FOLD ON DOTTED LINE

(1/8")

DRILL 3.2mm HOLE

(2 PLACES)

PLACE AGAINST DOOR

(11/16")

DRILL 16mm HOLE

TEMPLATE

PLACE AGAINST JAMB

OPPOSITE HINGES FOR

L.H.R. DOOR INSTALLATION

PLACE AGAINST HEADER

185mm ARMATURE PLATE GUIDE PIN HOLE

[6mm(1/4") DIA, 12.5mm(1/2") DEEP]

185mm ARMATURE PLATE

[6mm(1/4") DIA, 12.5mm(1/2") DEEP]

PLACE AGAINST JAMB

OPPOSITE HINGES FOR

R.H.R. DOOR INSTALLATION

STEP 1

FOLD TEMPLATE ALONG DOTTED LINE.
PLACE TEMPLATE AGAINST DOOR AND HEAD FRAME.
DRILL HOLES AS INDICATED ON TEMPLATE.

STEP 2

MOUNT THE ARMATURE PLATE TO DOOR USING

1 RUBBER WASHER SANDWICHED BETWEEN 2 STEEL

WASHER (THE RUBBER WASHER AND 2 STEEL

WASHER ARE INSTALLED ON THE THROUGH SEXNUT

BETWEEN THE ARMATURE PLATE AND DOOR).

STEP 3

DETACH MOUNTING PLATE FROM MAGNET BY REMOVING

2 SOCKET CAP SCREWS. SCREWS COULD BE ACCESSED

THROUGH BOTTOM OF MAGNET.

INSTALL THE MOUNTING PLATE WITH 2 FLAT HEAD

SCREWS (THE 2 M5x15 FLAT HEAD SCREWS ARE

INSTALLED IN THE SLOTTED HOLES FOR ADJUSTMENT).
ADJUST MOUNTING PLATE SO THAT IT FORMS A RIGHT

ANGLE WITH THE ARMATURE PLATE.


USING THE MOUNTING PLATE AS A TEMPLATE,DRILL

THE WIRE HOLE.

DRILL AND INSTALL THE REMAINING MOUNTING SCREWS.

STEP 4

INSTALL MAGNET TO MOUNTING PLATE WITH

2 M6 SCREWS SUPPLIED.

INSTALL ELECTRICAL WIRING PER

INSTRUCTION SHEET.

STEP 5

TEST ALL FUNCTIONS OF THIS MODEL (SEE

WIRING INSTRUCTION).

STEP 6

INSERT 2 LOCKING STOPPERS IN TWO END

PLATES,AND COVER WITH 4 mm SCREWS.

STEP 7

INSERT 2 ALUMINUM CAPS TO COVER THE

TWO M6 SCREW HOLES.

STEP 8

NOTE: IF NEEDED, USE SMALL MAGNET TO

REMOVE LOCKING STOPPERS FROM HOLES.

DWG. NO. 820001

Page 2 of 4  

75.5366.08 UL MAGLOCKS 600lb 20210806

 

5

Handle the equipment with care.  Damaging the mating surfaces of the magnet and armature plate may reduce locking efficiency.

 

5

The maglock mounts rigidly to the door frame.   The armature plate mounts to the door with the hardware provided.  This allows 

the armature plate to pivot about its center to compensate for door wear and misalignment.

 

5

Template use must take place with the door in its normally closed position.

 

5

Add threadlocker to all screws before installing, and firmly tighten screws.

 

5

Install only for indoor, dry applications.

 

5

Installation and wiring must be performed in compliance with ANSI/NFPA70 regulations.

 

5

The Maglock shall be installed within the same room as other equipment and circuitry connecting to the Maglock (per UL 864).

 

5

Shut off all power going to door or header before attempting any wiring procedures.

 

5

Maintain a clean and safe environment when working in public areas.

 

5

Constantly be aware of pedestrian traffic around the door area.

 

5

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions 

by the door.

 

5

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires 

and cause damage to equipment or cable insulation.

 

5

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

DO NOT over-tighten the armature plate.  

The rubber washer is designed to allow the armature plate to automatically adjust position for best mating position between the magnet and armature plate.

DOOR FRAME

DOOR FRAME

DOOR FRAME

MAGNET

MAGNET

MAGNET

DOOR

DOOR

DOOR

MOUNTING PLATE

Use the applicable mounting template.  

See image of template below.

See User’s Guide 75.5643 for U-bracket 

installation (to be used with glass doors).

MOUNTING PLATE

L&Z BRACKET

FILLER

ARMATURE PLATE

ARMATURE PLATE

ARMATURE PLATE

Filler

L&Z bracket

3   Precautions

4   Installation Notes

5   Installation 

 Mechanical

Mounting Options

TYPICAL INSTALLATION

!

CAUTION

Summary of Contents for UL MAGLOCKS 600LB

Page 1: ... 1 Description DESCRIPTION 10MAGLOCK3UL 10MAGLOCK3ULDS 10MAGLOCK6UL 10MAGLOCK6ULDS Lock single dual Input Voltage 12 or 24 VDC 12 or 24 VDC Relay Rating 1 0 A 24 VDC resistive 1 0 A 24 VDC resistive Reed Switch Rating SPDT 0 5 amp 30 VAC VDC resistive SPDT 0 5 amp 30 VAC VDC resistive Power Consumption 505 mA 12 VDC 260 mA 24 VDC 505 2 mA 12 VDC 260 2 mA 24 VDC Dimensions 9 84 x 1 65 x 1 02 in 250...

Page 2: ...ocking efficiency 5 The maglock mounts rigidly to the door frame The armature plate mounts to the door with the hardware provided This allows the armature plate to pivot about its center to compensate for door wear and misalignment 5 Template use must take place with the door in its normally closed position 5 Add threadlocker to all screws before installing and firmly tighten screws 5 Install only...

Page 3: ...black plastic piece of the armature plate with the cover plate i e magnet must line up with the switch 6 Armature Plate Installation Hole For Guide Pin Hole For Nut Steel Washer Rubber Washer Steel Washer Armature Plate Nut Spacer Door Screw M8 35mm Guide Pin The product must be powered from a UL listed regulated power limited power supply If power switch is not wired between DC source voltage and...

Page 4: ...LIGHT COM REED SWITCH ON DOOR STATUS SENSOR SWITCH Switch changes state when door is open NO BEA Inc the sensor manufacturer cannot be held responsible for incorrect installations or incorrect adjustments of the sensor device therefore BEA Inc does not guarantee any use of the sensor device outside its intended purpose BEA Inc strongly recommends that installation and service technicians be AAADM ...

Reviews: