BEA PHOENIX EX Quick Start Manual Download Page 1

PHOENIX EX™

5

1

2

4

3

75.5863.04 PHOENIX EX 20210701  

Page 1 of 8

Motion Sensor with Explosion-Proof Housing 

and Tamper Alert

1.  Explosion-proof housing
2.  Microwave sensor
3.  Grounding lug
4.  Cable port (¾” NPT pipe thread)
5.  Adjustable bracket

PHOENIX EX™:  for normal to high mounting (11.5 – 23 ft) 

PHOENIX EX™XL:  for low mounting (6.5 – 11.5 ft)

PHOENIX EX™WIDE:  for wide detection field (11.5 – 21 ft)

Visit website for 
available languages of 
this document.

DESCRIPTION

ENGLISH

Summary of Contents for PHOENIX EX

Page 1: ...Explosion proof housing 2 Microwave sensor 3 Grounding lug 4 Cable port NPT pipe thread 5 Adjustable bracket PHOENIX EX for normal to high mounting 11 5 23 ft PHOENIX EX XL for low mounting 6 5 11 5 ft PHOENIX EX WIDE for wide detection field 11 5 21 ft Visit website for available languages of this document DESCRIPTION ENGLISH ...

Page 2: ...t 8 2ft PHOENIX EX WIDE 30 x 11ft 21ft typical at 30 and field size 9 Min detection speed 2 in s Supply voltage 12 24 VAC 10 12 24 VDC 30 10 Mains frequency 50 60 Hz Max power consumption 2W Output max voltage max current max power relay free of potential change over contact 42V AC DC 1A resistive 30 W DC 60 VA AC Optional end of line resistor s 1 8 Watt Temperature range 22 140 F Housing certific...

Page 3: ...ode cycle the power For the first minute you can access the sensor without an access code SAVING AN ACCESS CODE DELETING AN ACCESS CODE DELETING AN UNKNOWN ACCESS CODE START END AN ADJUSTMENT SESSION press and hold either push button until the LED flashes or stops flashing SCROLL THROUGH PARAMETERS press the right push button CHANGE VALUE OF CHOSEN PARAMETER press the left push button RESET TO FAC...

Page 4: ...rizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the desired angle TRANSIENT SUPPRESSION DEVICE TO USER PANEL SENSOR OUTPUT Connect the wires to the controller PCB i e intrusion detection system If necessary an optional grounding lug is provided to ground the equipment to minimize the risk of electrostatic charge The equipment must be installed in ...

Page 5: ...n towards sensor uni AWAY one way detection away from sensor A active output relay energizes upon detection P passive output relay de energizes upon detection PHOENIX EX Mounting height 16 ft PHOENIX EX WIDE Mounting height 11 5 ft PHOENIX EX XL Mounting height 8 ft DETECTION FIELD DIMENSIONS SETTINGS To make adjustments to the sensor press 7 0 1 2 1 1 FIELD SIZE Parameter number 2 HOLD OPEN TIME ...

Page 6: ...of all targets pedestrians and parallel traffic are detected 1 no specific filter 2 filter against disturbances recommended in case of vibrations rain etc Detection only of vehicles moving pedestrians and parallel traffic are not detected disturbances are filtered The vehicle detection filter increases the response time of the sensor Always check if the chosen value is optimal for the application ...

Page 7: ... and the sensor detects raindrops or vibrations Ensure detection mode is unidirectional Increase detection filter value In highly reflective environments the sensor detects objects outside of its detection field Change the antenna angle Reduce field size Increase detection filter value Vehicle detection filter is used but pedestrians are still detected Chosen value is not optimal for the given app...

Page 8: ... national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer s recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed during each service call examples of these safety inspections can be...

Reviews: