Before launching a teach-in, ensure the following:

•  door is closed (use Service Mode if needed − see page 4)
•  both relays are connected to door control and master/slave cable is connected between sensors
•  detection field is free of environmental obstructions, objects, and people
•  laser window protector is removed

< 1 sec.

1.

2.

4.

3.

1.  Press the Master sensor push-button briefly.  The LED will begin quickly flashing red/green. When installing the 

sensor on a pair of doors, repeat this on the second Master sensor. 

2.  When both sensors flash green, position yourself in front of the door and stretch out your arm in front of you. 

Make an up-and-down motion at the leading-edge to mark the limit of the detection zones. The LED will flash 
red while calculating the width of the door leaves.

3.  When the sensors flash green again, remove yourself from the detection field and cycle the door open to allow 

the sensors to learn the environment.  The sensors will flash red during the closing of the door.

4.  Once the door is completely closed again and the LED is off, the teach-in is complete.

NOTE:

 

A teach-in on the master configures both the master and the slave. A teach-in on the slave only configures the 
slave.  In case the master and slave sensor are not aligned, first launch a teach-in on the master and then on the 
slave.

MASTER

TEACH-IN

TESTING / ADJUSTING

4

5

B

A

B

A

Always launch a teach-in and test the correct positioning of the detection fields after making adjustments to 

the angle, sensor position, or environment.

Check the correct positioning of the 
safety fields by walk-testing according 
to ANSI 156.10 standards.

If necessary, adjust the tilt angle of the laser curtain by turning the tilt 
angle adjustment screw (from 2° to 10°).

Summary of Contents for LZR-FLATSCAN SW

Page 1: ...ed Visit www BEAinc com for full User s Guide Do not remove the laser window protection during construction Position mounting base on door frame and mark and drill holes Remove cover pass cable through and secure sensor to mounting base Connect black plug to black connector Tighten lock screw Secure mounting base to door frame Drill pass thru hole in mounting base and route master slave cable If i...

Page 2: ...2 REOPENING impulse on approach side of door After changing a DIP switch the orange LED flashes A LONG push on the push button confirms the settings Afterwards a number of green flashes x indicates the number of connected sensors x X ORANGE OFF GREEN 3 sec ON switch OFF switch ON OFF DIP 2 ENVIRONMENT standard critical Switch to CRITICAL when external disturbances are likely to cause unwanted dete...

Page 3: ... LED will flash red while calculating the width of the door leaves 3 When the sensors flash green again remove yourself from the detection field and cycle the door open to allow the sensors to learn the environment The sensors will flash red during the closing of the door 4 Once the door is completely closed again and the LED is off the teach in is complete NOTE A teach in on the master configures...

Page 4: ...ed ensuring that the sensor system installation is compliant with local national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed...

Reviews: