WIRING

DIP SWITCHES

2

3

+

-

12-24 VDC

COM

NO/NC

COM

NO/NC

*

*

POWER SUPPLY

TEST

STOP IMPULSE

Opening side of the door

REOPENING IMPULSE

Closing side of the door

RED

BLACK

BLUE

BROWN

GREEN

WHITE

PURPLE
PURPLE

*  

output status when sensor is operational (can be NO or NC)

RELAY 1

RELAY 2

Install door loop.  

Cut the power cable to the right length, strip the 8 wires, 

and connect all wires as indicated above.

ON

1  2   3  4

ON

1  2   3  4

RELAY 1: STOP-impulse on swing side of door

RELAY 2: REOPENING-impulse on approach side of door 

After changing a DIP-switch, the orange LED flashes. 

A LONG push on the push button confirms the settings.

Afterwards, a number of green flashes (x) indicates the 

number of connected sensors (x).

X

ORANGE

OFF

GREEN

> 3 sec.

ON (switch 

)

OFF (switch 

)

ON

OFF

DIP 2

ENVIRONMENT

standard

critical

Switch to CRITICAL when external disturbances are likely 
to cause unwanted detections (min. obj size, immunity and 
uncovered zone are increased).

DIP 3

OUTPUT
CONFIGURATION

N.O./N.O.

1

N.C./N.C.

1

Settings for this DIP switch must be set on the master sensor 
(i.e. the sensor connected to the door control).

DIP 4

PINCH ZONE

on

off

Switch to OFF when the hinge area does not need to be 
secured and objects can cause unwanted detections.

NOTES

:

1.  RELAY 1 / RELAY 2

Summary of Contents for LZR-FLATSCAN SW

Page 1: ...ed Visit www BEAinc com for full User s Guide Do not remove the laser window protection during construction Position mounting base on door frame and mark and drill holes Remove cover pass cable through and secure sensor to mounting base Connect black plug to black connector Tighten lock screw Secure mounting base to door frame Drill pass thru hole in mounting base and route master slave cable If i...

Page 2: ...2 REOPENING impulse on approach side of door After changing a DIP switch the orange LED flashes A LONG push on the push button confirms the settings Afterwards a number of green flashes x indicates the number of connected sensors x X ORANGE OFF GREEN 3 sec ON switch OFF switch ON OFF DIP 2 ENVIRONMENT standard critical Switch to CRITICAL when external disturbances are likely to cause unwanted dete...

Page 3: ... LED will flash red while calculating the width of the door leaves 3 When the sensors flash green again remove yourself from the detection field and cycle the door open to allow the sensors to learn the environment The sensors will flash red during the closing of the door 4 Once the door is completely closed again and the LED is off the teach in is complete NOTE A teach in on the master configures...

Page 4: ...ed ensuring that the sensor system installation is compliant with local national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed...

Reviews: