WIRING
DIP SWITCHES
2
3
+
-
12-24 VDC
COM
NO/NC
COM
NO/NC
*
*
POWER SUPPLY
TEST
STOP IMPULSE
Opening side of the door
REOPENING IMPULSE
Closing side of the door
RED
BLACK
BLUE
BROWN
GREEN
WHITE
PURPLE
PURPLE
*
output status when sensor is operational (can be NO or NC)
RELAY 1
RELAY 2
Install door loop.
Cut the power cable to the right length, strip the 8 wires,
and connect all wires as indicated above.
ON
1 2 3 4
ON
1 2 3 4
RELAY 1: STOP-impulse on swing side of door
RELAY 2: REOPENING-impulse on approach side of door
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
Afterwards, a number of green flashes (x) indicates the
number of connected sensors (x).
X
ORANGE
OFF
GREEN
> 3 sec.
ON (switch
)
OFF (switch
)
ON
OFF
DIP 2
ENVIRONMENT
standard
critical
Switch to CRITICAL when external disturbances are likely
to cause unwanted detections (min. obj size, immunity and
uncovered zone are increased).
DIP 3
OUTPUT
CONFIGURATION
N.O./N.O.
1
N.C./N.C.
1
Settings for this DIP switch must be set on the master sensor
(i.e. the sensor connected to the door control).
DIP 4
PINCH ZONE
on
off
Switch to OFF when the hinge area does not need to be
secured and objects can cause unwanted detections.
NOTES
:
1. RELAY 1 / RELAY 2