QUICK GUIDE

MOUNTING

LZR

®

-FLATSCAN SW

ENGLISH

1

Safety sensor for full- and low-energy automatic swing doors

(US version)

Only trained and 

qualified personnel are 

recommended to install 

and set up the sensor. 

Always test for proper 

operation before leaving 

the premises.

The door control unit 

and the header cover 

profile must be correctly 

grounded. 

Visit www.BEAinc.com 

for full User’s Guide.

Do not remove the laser 

window protection during 

construction.

Position mounting base on door 

frame and mark and drill holes.

Remove cover, pass cable 

through, and secure sensor to 

mounting base.

Connect black plug to black 

connector.

Tighten lock screw.

Secure mounting base to door 

frame.

Drill pass-thru hole in mounting 

base and route master/slave 

cable.

If installing only one sensor (low-energy, approach side), disregard steps associated with the pass-thru cable.

READ BEFORE BEGINNING INSTALLATION & SET-UP

!

!

For applications requiring a spacer, first mount spacer to door, and then mount mounting base to spacer.

Summary of Contents for LZR-FLATSCAN SW

Page 1: ...ed Visit www BEAinc com for full User s Guide Do not remove the laser window protection during construction Position mounting base on door frame and mark and drill holes Remove cover pass cable through and secure sensor to mounting base Connect black plug to black connector Tighten lock screw Secure mounting base to door frame Drill pass thru hole in mounting base and route master slave cable If i...

Page 2: ...2 REOPENING impulse on approach side of door After changing a DIP switch the orange LED flashes A LONG push on the push button confirms the settings Afterwards a number of green flashes x indicates the number of connected sensors x X ORANGE OFF GREEN 3 sec ON switch OFF switch ON OFF DIP 2 ENVIRONMENT standard critical Switch to CRITICAL when external disturbances are likely to cause unwanted dete...

Page 3: ... LED will flash red while calculating the width of the door leaves 3 When the sensors flash green again remove yourself from the detection field and cycle the door open to allow the sensors to learn the environment The sensors will flash red during the closing of the door 4 Once the door is completely closed again and the LED is off the teach in is complete NOTE A teach in on the master configures...

Page 4: ...ed ensuring that the sensor system installation is compliant with local national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed...