6
PARAMETER SETTINGS
(1)
(2)
(3)
(4)
(5)
(6)
(11) Detection field 1 (W)
(12) Detection field 1 (H)
(13) Detection field 2 (W)
(16) Check Values
(17) Lock
(18) Output configuration
(20) Multifunction key * 2
(7)
(8)
(9)
(10)
(14) Detection field 2 (H)
* 1
(15) Uncovered zone
(19) Antimasking & Background
(21) Immunity filter
(22) LED activation
* 1. Mounting side: right
* 2. Match with other keys to change among different
functions
VISIBLE
SPOTS
turn on /off the visble spots.
- Confirm the wiring of the scanner.
- Power on.
- Switch on the visible spots, then align the curtain position precisely (refer to remote control instruction).
Adjust the tilt angle (with universal bracket) to make sure the curtain covers the detection area
approximately if necessary .
- The shape of laser spot is oval, the further the laser spot shoots ,the bigger the spot diffuses, refer to
below diagram to calculate the position to prevent spot shooting on train body.
- Visible spots are used for the estimation of curtain coverage during the initial adjustment stage. For
precise installation of the sensor, please evaluate your detection field and adjust curtain accordingly.
ALIGNMENT
Visible spot
Laser beam
43mm
21.5mm
Distance (m)
b (mm)
a (mm)
1
12.5
1.5
2
25
3
3
37.5
4.5
4
50
6
5
62.5
7.5
a= width
b
=
hei
gh
t
Do not look into the visible beams directly!
The visible spot has around ±1.5cm deviation at 3m distance, please make sure the curtain is in the
right position.
0-9 Number keys
Detection field
Redirection
Plus
Unlock
Minus
Output activation delay
Min. object size
Detection area activation
Mounting side
Fog filter
* For more information on the visible spot and its calculations, please refer to our
Application Note
.