INSTALLATION
DIP SWITCH
DIP 2 ENVIRONMENT
DIP 3 BACKGROUND
DIP 4 OUTPUT CONFIGURATION
standard
critical*
DIP 5 (NOT USED)
DIP 1 MONITORING
active high
active low
POWER SUPPLY
TEST / MONITOR
R1(RELAY)
R2(OPTO)
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED
BLUE
*
Output status when sensor is operational.
INSTALLATION OF THE SENSOR
Install the sensor at the right position and fix it with the screws.
* When DIP2 is OFF (critical environments),
testbody
CB
(DIN 18650-1) might not be detected.
Switch to CRITICAL when external disturbances are likely to
cause unwanted detections.
Switch to OFF when there is no background
(e.g. glass floor).
Make sure the front side of the sensor faces towards the
outside of the door
WIRING
For compliance with EN 16005 and DIN 18650-1, the door controller test output must be connected and able
to test the sensor.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
recommended position
front side
Make sure that the distance between the centre of the
sensor and the leading post is not smaller than 20 cm.
on
NC
> 3 sec.