User’s Guide for product version 

0100

 and higher

COMPACT LASER SCANNER FOR THE SAFETY OF 

REVOLVING DOORS

EN

Summary of Contents for LZR- FLATSCAN REV-PZ

Page 1: ... A C C O R D A N C E W I T H E R L A U B T Z E R T I F I Z I E R U N G N A C H EN 16005 E N A B L E S A C C O R D A N C E W I T H PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING User s Guide for product version 0100 and higher COMPACT LASER SCANNER FOR THE SAFETY OF REVOLVING DOORS EN ...

Page 2: ...3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION Caution Laser radiation Remote control sequence Possible remote control adjustments Factory values Attention Note The LZR FLATSCAN REV PZ is a safety sensor for automatic revolving doors based on laser technology It secures the area in front of the leading post of the drum wall p...

Page 3: ... carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel IN...

Page 4: ...on and fix it with the screws When DIP2 is OFF critical environments testbody CB DIN 18650 1 might not be detected Switch to CRITICAL when external disturbances are likely to cause unwanted detections Switch to OFF when there is no background e g glass floor Make sure the front side of the sensor faces towards the outside of the door WIRING For compliance with EN 16005 and DIN 18650 1 the door con...

Page 5: ... 7cm VISIBLE SPOTS ADJUSTMENTS SETTINGS Quickly press the push button twice to activate the visible spots they will help you position the curtain Quickly press twice to activate or deactivate the visible laser spots Press for 2 seconds to launch a teach in process Press for 3 seconds to confirm the setting after changing the DIP switch Press for 5 seconds to acknowledge the 6x flashing error messag...

Page 6: ...sensor flashes green Stretch out your arm in front of you and make an up and down movement to define the left right limit of the detection field The LED flashes red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED flashes red while calculating 4 Once the ...

Page 7: ...covered zone increase in case of snow dead leaves etc Measured in specific conditions and dependant on application and installation DETECTION FIELD A new teach in overwrites these values HOLD TIME UNCOVERED ZONE Right detection area Left detection area OUTPUT REDIRECTION In case of false detection button and are not recommended When DIP2 is OFF change automatically to 10 cm In order to change thes...

Page 8: ...or without introducing any access code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS DETECTION FIELD ADJUSTMENT Launch detection field Teach in refer to the teach in process on page 6 Launch environment learning increase decrease the detection field of 1cm TEACH IN CHECKING A VALUE field width 2 35 m x number of flashes value of the parameter When there are s...

Page 9: ...s output redirection and configuration enable disable the LED when there is a detection disable the output and LED for during 15 minutes and can be useful during an installation a mechanical teach in of the door or maintenance work LED ACTIVATION DEACTIVATION VISIBLE SPOTS SERVICE MODE RESET TO FACTORY SETTINGS ...

Page 10: ...rror Check voltage between red and blue wires The service mode is activated Exit the service mode It is not possible to adjust a setting with the remote control Wrong DIP switch position Adjust the required DIP switches to ON The sensor is password protected Enter the right password If you forgot the code cut and restore the power supply to access the sensor without entering a password during 1 mi...

Page 11: ... detection field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and clean it with compressed air Then wipe it carefully with a damp and clean microfibre cloth if necessary attention the surface of the laser window is delicate The sensor does not see it...

Page 12: ...estbody CB according to DIN 18650 1 3 5 m Optical characteristics IEC EN 60825 1 Wavelength 905 nm average output power 0 05 mW CLASS 1 Wavelength 650 nm max output CW power 3 mW CLASS 3R visible spot Supply voltage 12 24V DC 15 Power consumption 2 2 W Response time Max 90 ms Output 1 optocoupler galvanic isolation polarity free Max switching voltage 42V AC 60V DC Max switching current 100 mA 1 Re...