DIPSWITCH 
SETTINGS – Cont.

 

 
 
 
 
 

 
 

2.  Use the chart (at right) for a quick-reference for 

time  delay  settings  (switches  1  through  5). 
Factory setting is 7 seconds. 

 

 

Example

The normal closing cycle of an automatic door lasts 
about 7 seconds.  In order to get the proper closing 
lock  out  time  delay  needed  for  the  closing  cycle  of 
the  door,  the  dipswitches  need  to  be  set  according 
to  the  chart  on  page  3  for  7  seconds.    To  get  the 
proper  lock  out  time  delay  dip  switches  1,  2,  &  3 
must  be  in  the  ON  position  and  Dip  Switch  4  must 
be in the OFF position. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.  DIPSWITCH #6: Corresponds to the type of motor voltage logic on the RED and BLACK wires.  Dipswitch 6 should be 

on for all applications that have the red and black wires going to a parallel motor connection. Dipswitch 6 should be OFF 
for applications where voltage is present on the red and black wires at the closed door position, and where 0 volts is 
present at the door open position. 

4.  DIPSWITCH  7  OFF  &  8  ON:

 

Provides  a  CLOSED  circuit  between  the  GREEN  (COMMON)  and  YELLOW  (SAFETY) 

during BODYGUARD detection and an OPEN circuit at all other times. 

5.  DIPSWITCH 7 ON & 8 OFF: Provides a OPEN circuit between the GREEN (COMMON) and YELLOW (SAFETY) during 

BODYGUARD detection and a CLOSED circuit at all other times. (Example:  Besam PowerSwing). 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Dipswitch # 

Function 

OFF 

ON 

1  

Time Delay: 1 sec. value 

0 seconds 

1 second 

Time Delay: 2 sec. value 

0 seconds 

2 second 

Time Delay: 4 sec. value 

0 seconds 

4 second 

Time Delay: 8 sec. value 

0 seconds 

8 second 

Time Delay: 16 sec. value 

0 seconds 

16 second 

Voltage switching device 

Voltage source is other than motor 

Motor Voltage 

Safety circuit logic (used with DS #8) 

7 OFF / 8 ON = N/O Safety Circuit 

Safety circuit logic (used with DS #7) 

7 ON / 8 OFF = N/C Safety Circuit 

 

Seconds 

dip 1 

1 sec

 

dip 2 

2 sec

 

dip 3 

4 sec

 

dip 4 

8 sec

 

dip 5 

16 sec

 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

OFF

 

OFF

 

OFF

 

ON

 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

OFF

 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

OFF

 

OFF

 

ON

 

ON

 

OFF

 

OFF

 

ON

 

ON

 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

OFF

 

ON

 

OFF

 

10 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

11 

ON

 

ON

 

OFF

 

ON

 

OFF

 

12 

OFF

 

OFF

 

ON

 

ON

 

OFF

 

13 

ON

 

OFF

 

ON

 

ON

 

OFF

 

14 

OFF

 

ON

 

ON

 

ON

 

OFF

 

15 

ON

 

ON

 

ON

 

ON

 

OFF

 

16 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

17 

ON

 

OFF

 

OFF

 

OFF

 

ON

 

18 

OFF

 

ON

 

OFF

 

OFF

 

ON

 

19 

ON

 

ON

 

OFF

 

OFF

 

ON

 

20 

OFF

 

OFF

 

ON

 

OFF

 

ON

 

21 

ON

 

OFF

 

ON

 

OFF

 

ON

 

22 

OFF

 

ON

 

ON

 

OFF

 

ON

 

23 

ON

 

ON

 

ON

 

OFF

 

ON

 

24 

OFF

 

OFF

 

OFF

 

ON

 

ON

 

25 

ON

 

OFF

 

OFF

 

ON

 

ON

 

26 

OFF

 

ON

 

OFF

 

ON

 

ON

 

27 

ON

 

ON

 

OFF

 

ON

 

ON

 

28 

OFF

 

OFF

 

ON

 

ON

 

ON

 

29 

ON

 

OFF

 

ON

 

ON

 

ON

 

30 

OFF

 

ON

 

ON

 

ON

 

ON

 

31 

ON

 

ON

 

ON

 

ON

 

ON

 

Brand / Model Of Operator 

Dipswitch 6, 7 & 8 Setting 

Besam Swingmaster (ETIK) 

6 ON, 7 OFF, 8 ON 

Besam Swingmaster MP 
(CUP) 

6 OFF 7 OFF, 8 ON 

Besam PowerSwing 

6 ON, 7 ON, 8 OFF 

Doromatic Astro-Swing 
Mid-Swing 
Senior Swing 

6 ON, 7 OFF, 8 ON 

Gyro-Tech (all except Gemini 
710 AND U11) 

6 ON, 7 OFF, 8 ON 

Horton 4000 

6 ON, 7 OFF, 8 ON 

Horton 7000 

6 ON, 7 OFF, 8 ON 

KM 2000 

6 ON, 7 OFF, 8 ON 

Stanley Magic Swing 
Magic Force (with safety) 

6 ON, 7 OFF, 8 ON 

OBSOLETE

Summary of Contents for LO-21U

Page 1: ... 24 VDC Operating frequency 4 MHz Microprocessor Power consumption 10 mA at rest 50 mA Maximum Output 2 SPST Relays Maximum voltage Relay contacts 60 VDC 120 VAC Maximum current Relay contacts 2A DC 0 5 A AC Shut off all power going to the header before attempting any wiring procedures Maintain a clean safe environment when working in public areas Constantly be aware of pedestrian traffic around t...

Page 2: ... DC Green Door Control Common Blue Door Control Activate Yellow Door Control Safety 1 The dipswitches are located at the end of the LO 21U opposite of the wire connection terminal There are 8 positions available Dipswitch designations are as follows BLANK 1 INHIBIT GND 2 INHIBIT 3 N C 4 N O 5 COM 6 POWER 7 POWER 8 BLANK 1 INHIBIT GND 2 INHIBIT 3 N C 4 N O 5 COM 6 POWER 7 POWER 8 115 VAC BODYGUARD ...

Page 3: ... 0 seconds 1 second 2 Time Delay 2 sec value 0 seconds 2 second 3 Time Delay 4 sec value 0 seconds 4 second 4 Time Delay 8 sec value 0 seconds 8 second 5 Time Delay 16 sec value 0 seconds 16 second 6 Voltage switching device Voltage source is other than motor Motor Voltage 7 Safety circuit logic used with DS 8 7 OFF 8 ON N O Safety Circuit 8 Safety circuit logic used with DS 7 7 ON 8 OFF N C Safet...

Page 4: ...wires Also make sure the LO 21U has the proper input voltage at the orange and brown wires 5 Once the Bodyguard is functioning correctly with regard to the open and closed door setup walk testing may begin q Do NOT proceed with walk test until the Bodyguard is functioning correctly 6 The LO 21U has two LED s to indicate what function it is performing When the door is closed and someone steps into ...

Page 5: ...62 from 7am 5pm For after hours call East Coast 1 866 836 1863 or 1 800 407 4545 Mid West 1 888 308 8843 West Coast 1 888 419 2564 DO NOT leave any problem unresolved If you must wait for the following workday to call B E A leave the door inoperable until satisfactory repairs can be made NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution Web www beasensors ...

Reviews: