75.1041.08 LO21U 20150708
Page 3 of 5
DIPSWITCH
SETTINGS – Cont.
2. Use the chart (at right) for a quick-reference for
time delay settings (switches 1 through 5).
Factory setting is 7 seconds.
Example
:
The normal closing cycle of an automatic door lasts
about 7 seconds. In order to get the proper closing
lock out time delay needed for the closing cycle of
the door, the dipswitches need to be set according
to the chart on page 3 for 7 seconds. To get the
proper lock out time delay dip switches 1, 2, & 3
must be in the ON position and Dip Switch 4 must
be in the OFF position.
3. DIPSWITCH #6: Corresponds to the type of motor voltage logic on the RED and BLACK wires. Dipswitch 6 should be
on for all applications that have the red and black wires going to a parallel motor connection. Dipswitch 6 should be OFF
for applications where voltage is present on the red and black wires at the closed door position, and where 0 volts is
present at the door open position.
4. DIPSWITCH 7 OFF & 8 ON:
Provides a CLOSED circuit between the GREEN (COMMON) and YELLOW (SAFETY)
during BODYGUARD detection and an OPEN circuit at all other times.
5. DIPSWITCH 7 ON & 8 OFF: Provides a OPEN circuit between the GREEN (COMMON) and YELLOW (SAFETY) during
BODYGUARD detection and a CLOSED circuit at all other times. (Example: Besam PowerSwing).
Dipswitch #
Function
OFF
ON
1
Time Delay: 1 sec. value
0 seconds
1 second
2
Time Delay: 2 sec. value
0 seconds
2 second
3
Time Delay: 4 sec. value
0 seconds
4 second
4
Time Delay: 8 sec. value
0 seconds
8 second
5
Time Delay: 16 sec. value
0 seconds
16 second
6
Voltage switching device
Voltage source is other than motor
Motor Voltage
7
Safety circuit logic (used with DS #8)
7 OFF / 8 ON = N/O Safety Circuit
8
Safety circuit logic (used with DS #7)
7 ON / 8 OFF = N/C Safety Circuit
Seconds
dip 1
1 sec
dip 2
2 sec
dip 3
4 sec
dip 4
8 sec
dip 5
16 sec
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
5
ON
OFF
ON
OFF
OFF
6
OFF
ON
ON
OFF
OFF
7
ON
ON
ON
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
9
ON
OFF
OFF
ON
OFF
10
OFF
ON
OFF
ON
OFF
11
ON
ON
OFF
ON
OFF
12
OFF
OFF
ON
ON
OFF
13
ON
OFF
ON
ON
OFF
14
OFF
ON
ON
ON
OFF
15
ON
ON
ON
ON
OFF
16
OFF
OFF
OFF
OFF
ON
17
ON
OFF
OFF
OFF
ON
18
OFF
ON
OFF
OFF
ON
19
ON
ON
OFF
OFF
ON
20
OFF
OFF
ON
OFF
ON
21
ON
OFF
ON
OFF
ON
22
OFF
ON
ON
OFF
ON
23
ON
ON
ON
OFF
ON
24
OFF
OFF
OFF
ON
ON
25
ON
OFF
OFF
ON
ON
26
OFF
ON
OFF
ON
ON
27
ON
ON
OFF
ON
ON
28
OFF
OFF
ON
ON
ON
29
ON
OFF
ON
ON
ON
30
OFF
ON
ON
ON
ON
31
ON
ON
ON
ON
ON
Brand / Model Of Operator
Dipswitch 6, 7 & 8 Setting
Besam Swingmaster (ETIK)
6 ON, 7 OFF, 8 ON
Besam Swingmaster MP
(CUP)
6 OFF 7 OFF, 8 ON
Besam PowerSwing
6 ON, 7 ON, 8 OFF
Doromatic Astro-Swing
Mid-Swing
Senior Swing
6 ON, 7 OFF, 8 ON
Gyro-Tech (all except Gemini
710 AND U11)
6 ON, 7 OFF, 8 ON
Horton 4000
6 ON, 7 OFF, 8 ON
Horton 7000
6 ON, 7 OFF, 8 ON
KM 2000
6 ON, 7 OFF, 8 ON
Stanley Magic Swing
Magic Force (with safety)
6 ON, 7 OFF, 8 ON
OBSOLETE