BEA IXIO-DO1 I User Manual Download Page 8

BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM

©

BE

A

 

 | 

O

ri

gi

na

l i

ns

tr

uc

ti

on

s

 |

 

4

2

.8

35

6 / V

4

 -

 0

5.

18

BEA hereby declares that the IXIO-DO1 I is in conformity with the basic requirements and the other relevant provisions of the 
directives 2014/53/EU and 2011/65/EU.

The complete declaration of conformity is available on our website.

Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Elec

tronic Equipment (WEEE)

TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Norms conformity:

Presence

Typical response time: < 200 ms (max. 500 ms)

Active infrared with background analysis

Spot: 5 cm x 5 cm (typ)

Number of spots: max. 24 per curtain

Number of curtains: 2

Solid-state-relay (potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Holdtime: 0.3 to 1 s

Motion

Min. detection speed: 5 cm/s

Microwave doppler radar

Transmitter frequency: 24.150 GHz

Transmitter radiated power: < 20 dBm EIRP

Transmitter power density: < 5 mW/cm

2

Solid-state-relay (potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Detection mode:

Technology:

Output:

Specifications are subject to changes without prior notice.
All values are measured in specific conditions and with a temperature of 25°C.

12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%  

(to be operated from SELV compatible power supplies only)

< 2.5 W
2 m to 4 m

 

(according to the applicable laws and regulations)

-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
EN 300 440-2 V1.4.1; EN 301 489-1 V1.9.2; EN 301 489-3 V1.6.1; EN 62311; EN 62479; EN 50581

PL

EA

SE K

EE

P F

O

R F

U

R

TH

ER U

SE - D

ES

IG

N

ED F

O

R C

O

LO

U

R P

R

IN

TI

N

G

Summary of Contents for IXIO-DO1 I

Page 1: ...main adjustment knob 9 IR curtain angle adjustment knob Opening safety sensor for automatic industrial doors User s Guide for product version 0403 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory RA Rain accessory Download the BEA DECODER app for a quick overview of settings 9 V battery ENGLISH ...

Page 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Page 3: ...immunity 2 field size 9 immunity 2 field size 9 immunity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor GREEN BROWN YELLOW WHITE PINK GREY RED BLUE POWER SUPPLY OPENING INPUT SAFETY INPUT NOT USED Output status when sensor is operational from 15 to 45 default 30 from 15 to 15 default 0 SENSOR ENGLISH IXIO DO1 I INSTALLATION GUIDE ...

Page 4: ...t visible use the Spotfinder to locate the curtains The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weather SHOPPING STREET installations in narrow streets with pedestrian traffic Choose one o...

Page 5: ...r should have a different frequency increased immunities 1 curtain increased immunities redirection motion and presence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic ada...

Page 6: ...ened firmly Check position of cable and cover Increase the IR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Repl...

Page 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Page 8: ...typ Number of spots max 24 per curtain Number of curtains 2 Solid state relay potential and polarity free Max contact current 100 mA Max contact voltage 42 V AC DC Holdtime 0 3 to 1 s Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW cm2 Solid state relay potential and polarity free Max c...

Reviews: