Page 6 of 9 

75.5695.07 IS40 IS40XL 20170313

3

4

5

6

1

2

XXS

XS

S

>

>

>

>

L

XL

XXL

0.5 s

1 s

2 s

3 s

4 s

5 s

6 s

7 s

8 s

9 s

Mounting Height

8 ft

10 ft

11.5 ft

13 ft
16 ft

Maximum Mounting Height

IS40XL                        11.5 ft

IS40                            16 ft

Width *

5 ft
7 ft

7.5 ft

8.5 ft

10 ft

Depth *

5 ft
7 ft

7.5 ft

8.5 ft

10 ft

OUTPUT 

CONFIGURATION

PRESENCE RELAY

IS40 / IS40XL

LED

0 - 6:  ALL MODES

Activates when object is in presence zone.

ACTIVATION RELAY

IS40 / IS40XL

LED

0:  STANDARD MODE

Activates when motion detected.

1:  PULSE ON ENTRY

Activates if object motion is detected and then object 

enters presence zone.

2:  PULSE ON EXIT

Activates if object motion is detected and then object exits 

presence zone.

3:  PULSE ON ENTRY FIRST / LAST LINE

     (See Example to the Left)

Activates if object motion is detected and then object 

enters presence zone (first or last line).

4:  PULSE ON EXIT FIRST / LAST LINE

     (See Example to the Left)

Activates if object motion is detected and then object exits 

presence zone (first or last line).

5:  REMAINS ACTIVE UNTIL PRESENCE 

     ZON E IS CLEARED (Regardless of Motion)

Activates when motion is detected and remains active until 

the presence zone is cleared.

6:  REMAINS ACTIVE UNTIL PRESENCE

     ZONE IS CLEARED (Regardless of Motion)

Activates when motion is detected and AIR is detected and 

remains active until the presence zone is cleared.

bi

uni

POSSIBLE REMOTE CONTROL SETTINGS 

(motion sensing)

FIELD SIZE
(SENSITIVITY)

DETECTION MODE

uni

AWAY

DETECTION FILTER
(REJECTION MODE)

bi = two-way detection

uni = one-way detection towards sensor

uni AWAY = one-way detection away from sensor

3     Low ‘Pedestrian/Parallel traffic’ Rej Interference    

         Immunity

4     Medium ‘Pedestrian/Parallel traffic’ Rej Interference       

       Immunity

5     High ‘Pedestrian/Parallel traffic’ Rej Interference     

         Immunity

6     Extra High ‘Pedestrian/Parallel traffic’ Rej           

       Interference Immunity

1    Detection of all kind of Targets in Motion
2    Detection of all kind of Targets in     

        Interference Immunity

    

Detection of ALL TARGETS

(pedestrians, vehicles and parallel traffic are detected)

Detection only of VEHICLES MOVING TOWARDS THE SENSOR

(pedestrians and parallel traffic are not de immunity filter)

AIR PATTERN SIZE AT 15

O

 SENSOR ANGLE

Approximate default AIR pattern size using a 15º sensor tilt angle. The higher the mounting height the larger the AIR 
pattern.

*      Dimensions are approximate.

HOLD-OPEN TIME

Red

Green 

DOOR  EXAMPLE

First Line

Last Line

Summary of Contents for IS40

Page 1: ...IS40 13ft x 16 5ft IS40 XL 13ft x 6 5ft 2 in s 100 ms 8 22 relative to sensor front face Supply voltage Power consumption Mains frequency Output Max contact voltage Max contact current Max switching power Mounting height Temperature range Humidity Degree of protection Dimensions Materials Weight Cable length Norm conformity Technology Transmitter frequency wavelength Output holdtime Transmitter po...

Page 2: ... any wiring procedures Maintain a clean safe environment Constantly be aware of pedestrian vehicle traffic around the area Always stop pedestrian vehicle traffic through the doorway when performing tests that may result in unexpected reactions by the door ESD electrostatic discharge Circuit boards are vulnerable to damage by electrostatic discharge Before handling any board ensure you dissipate yo...

Page 3: ...y within this minute an unknown access code may be deleted via the remote following the steps outlined below Press unlock lock 0 0 0 0 The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote control If the red LED flashes quickly after unlocking enter an access code from 1 to 4 digits If you do not know t...

Page 4: ...YELLOW BLACK Motion Relay Presence Relay 1 Active Passive 2 Passive Active 3 Passive Passive 4 Active Active Description Detection No Detection Active Relay COM COM Passive Relay COM COM NO NC NO NC NO NC NO NC RELAY CONFIGURATION COM NO NC COM NO NC RECOMMENDED The graphics above are not to scale and for illustration purposes and represent approximate detection fields when mounted at 16 ft 4 9m A...

Page 5: ... 8 ft 11 11 Adjust the field size S 2 L 7 Choose the right detection filter for your application By turning this screw the radar field angle can be adjusted from 8 to 22 p 6 p 6 RADAR FIELD AND AIR PATTERN The total angle is the sum of the sensor angle and the radar field angle All detection field dimensions were measured in optimal conditions and a sensitivity value of 7 Sensor angle 30 Radar fie...

Page 6: ... until the presence zone is cleared 6 REMAINS ACTIVE UNTIL PRESENCE ZONE IS CLEARED Regardless of Motion Activates when motion is detected and AIR is detected and remains active until the presence zone is cleared bi uni POSSIBLE REMOTE CONTROL SETTINGS motion sensing FIELD SIZE SENSITIVITY DETECTION MODE uni AWAY DETECTION FILTER REJECTION MODE bi two way detection uni one way detection towards se...

Page 7: ...ition within the AIR field is random low high 1 min 2 min 30 s 10 min 20 min 5 min 1 h 2 h 1 h 30 normal AIR PATTERN SIZE AVAILABLE TARGET SIZE 1 2 3 4 5 9 8 7 6 The target position within the AIR Field is random FACTORY VALUES RESETTING TO FACTORY VALUES Launch a setup to make a reference picture Step out of the detection field and do not leave any tools inside the detection field Upon power up t...

Page 8: ...field size Increase the detection filter value The door opens for no apparent reason The sensor detects raindrops or vibrations In highly reflective environments the sensor detects objects outside of its detection field The vehicle detection filter is used but pedestrians are still detected The chosen value is not optimal for the application Increase the detection filter value Change the sensor an...

Page 9: ...perform a safety inspection for the type of Door Gate per the manufacturer recommendations and or per ANSI DASMA guidelines for best industry practices Some examples but not limited to are ANSI DASMA 102 ANSI DASMA 107 UL 325 Make certain all appropriate industry warning labels are applied It is the responsibility of the installer service personell to be familiar with national and local codes stan...