Universal
Remote
Control Guide
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275
Phone: 1 412.249.4100
FAX: 1 888.523.2462
Toll Free: 1 800.523.2462
75.0180.05 20081021
* Active output (Fail-Secure):
NC-COM circuit is closed and
NO-COM circuit is open.
** Passive output (Fail-Safe):
NO-COM circuit is closed and
NC-COM circuit is open.
WIZARD
Microwave Sensitivity(0-9)
Default = 7
F1
Safety Output (0-1)
0. No Redirection (6 wires)
1. All Relay Output (4 wires)
Relay Output (1-4)
Motion Out
Presence Out
1. Active NO
Passive NC
2. Passive NC
Active NO
3. Passive NC
Passive NC
4. Active NO
Active NO
Detection Mode (1-4)
1.Bidirectional 2.Unidirectional
3.Unidirectional with MTF
4. Unidirectional Reverse
Microwave Immunity(1-9)
1. Reduced 2. Normal
3. Increased 4-9 Enhanced
Infrared Immunity (1-3)
1. Low 2. Medium 3. High
Set-Up (0 or 9)
0. Setup 9. Factory Defaults
FALCON
Sensitivity (0-9)
Default = 7
Hold Time (0-9)
(0.5 sec - 9 sec)
Relay Output (1-2)
1. Active Output*
2. Passive Output**
Detection Mode (1-3)
1.Bidirectional
2.Unidirectional Approach
3.Unidirectional Depart
Rejection Mode
(1-5)
1. Detects all traffic: Pedestrian
& Vehicle
2. Detects All TInterference
Immunity
3. Low Pedestrian/Parallel Traffic
Rejection
4. Mid Pedestrian/Parallel Traffic
Rejection
5. High Pedestrian/Parallel Traffic
Rejection
Restore Default
Settings (1)
Auto Learn Time(0-6 or 9)
0 - 30 sec 3 - 5 min 6 - 60 min
1 - 1 min 4 - 10 min
9 - Infinity
2 - 2 min 5 - 20 min (no learn)
EAGLE
Sensitivity (0-9)
Default = 8
Hold Time (0-9)
(0.5 sec - 9 sec)
Relay Output (1-2)
1. NO Relay* 2. NC Relay**
Detection Mode (1-3)
1. Bidirectional 2. Unidirectional
3. Unidirectional with MTF
Immunity (1-9)
1. Reduced 3. Increased
2. Normal 4-9. Enhanced
Default Settings(1-2 or 9)
1.Normal 2.Boost 9.Restore
F2
Door Control (1-3)
1. Normal
2. Permanent Detection
3. Permanent Non-Detection
75.0180.05_RC_Guide_20080915_BW.indd 1
75.0180.05_RC_Guide_20080915_BW.indd 1
10/21/2008 3:05:59 PM