background image

?

?

?

??

?

Universal 

Remote 

Control Guide

RIDC Park West

100 Enterprise Drive

Pittsburgh, PA 15275

   

Phone: 1 412.249.4100

      FAX: 1 888.523.2462

Toll Free: 1 800.523.2462

75.0180.05   20081021

  * Active output  (Fail-Secure):

     NC-COM circuit is closed and

     NO-COM circuit is open.

** Passive output (Fail-Safe):

     NO-COM circuit is closed and

     NC-COM circuit is open.

WIZARD

Microwave Sensitivity(0-9)

Default = 7 

F1

Safety Output (0-1)

0. No Redirection (6 wires)

1. All Relay Output (4 wires)

Relay Output (1-4)

 

Motion Out 

Presence Out

1. Active NO 

Passive NC

2. Passive NC 

Active NO

3. Passive NC 

Passive NC

4. Active NO 

Active NO

Detection Mode (1-4)

1.Bidirectional 2.Unidirectional

3.Unidirectional with MTF

4. Unidirectional Reverse

Microwave Immunity(1-9)

1. Reduced              2. Normal

3. Increased            4-9 Enhanced 

Infrared Immunity (1-3)

1. Low       2. Medium       3. High

Set-Up (0 or 9)

 

0. Setup     9. Factory Defaults

FALCON

Sensitivity (0-9)

Default = 7

Hold Time (0-9) 

(0.5 sec - 9 sec)

Relay Output (1-2)

1. Active Output*

2. Passive Output**

Detection Mode (1-3)

1.Bidirectional

2.Unidirectional Approach

3.Unidirectional Depart

Rejection Mode

(1-5)

1. Detects all traffic: Pedestrian 

    & Vehicle

2. Detects All TInterference 

    Immunity

3. Low Pedestrian/Parallel Traffic 

    Rejection

4. Mid Pedestrian/Parallel Traffic 

    Rejection

5. High Pedestrian/Parallel Traffic 

    Rejection

Restore Default 

Settings (1)

Auto Learn Time(0-6 or 9)

0 - 30 sec   3 - 5 min     6 - 60 min

1 - 1 min     4 - 10 min

    

9 - Infinity

2 - 2 min     5 - 20 min    (no learn) 

EAGLE

Sensitivity (0-9)

Default = 8 

Hold Time (0-9) 

(0.5 sec - 9 sec)

Relay Output (1-2)

1. NO Relay*     2. NC Relay** 

Detection Mode (1-3)

1. Bidirectional     2. Unidirectional 

3. Unidirectional with MTF

Immunity (1-9)

1. Reduced        3. Increased

2. Normal        4-9. Enhanced

Default Settings(1-2 or 9)

1.Normal     2.Boost     9.Restore

F2

Door Control (1-3)

1. Normal

2. Permanent Detection 

3. Permanent Non-Detection

75.0180.05_RC_Guide_20080915_BW.indd   1