24
25
CLOSE THE FUEL VALVE LEVER
Turn off the fuel valve lever after the shutdown of the unit.
Storage
DRAIN THE FUEL
PROTECTIVE TREATMENT
Remove the oil draining bolt of the carburetor and drain the fuel from the
fuel tank and carburetor Then tighten the oil draining bolt again if the fuel
is not drained the fuel will evaporate and flow into the air and the residues
may block the carburetor.
To prevent fuel spillage when transporting or during temporary storage,
the generator should be secured upright in its normal operating
position,with the engine switch OFF. The fuel valve lever should be turned
OFF.
The unit should be stored in a clean and dry place and should be
protected from rain and high temperature. Shield the unit with paper box
or plastic bag to prevent dust from entering the unit.
Transporting
WARNING
· Do not overfill the tank.
· Do not operate the generator while it is on a vehicle. Take the
generator off the vehicle and use it in a well ventilated place.
· Avoid a place exposed to direct sunlight when putting the generator
on a vehicle .If the generator is left in an enclosed vehicle for many
hours,high temperature inside the vehicle could cause fuel to vaporize
resulting in a possible explosion.
· Do not drive on a rough road for an extended period with the
generator on board. If you must transport the generator on a rough
road,drain the fuel from the generator beforehand.
NOTICE
· To transport the generator, hold the holding part (shaded areas in
Fig.1).
· Take care not to drop or strike the generator when transporting.
· Do not place heavy objects on the generator.
· When transporting the generator by loading it on to a vehicle, secure
to the generator frame as shown (see fig.2).
OPERATION
OPERATION