The air conditioner
The unit is not straight.
Use a spirit level to check the unit is
is leaking.
horizontal, if not remove from the wall
and Straighten.
The drain pipe is blocked.
Check the drain pipe to ensure it is
not blocked or constricted.
Compressor does
Overheat protection operational.
Wait for 3 minutes until the
not work.
temperature is lowered, and then
restart the machine.
The remote
The remote control is not aligned
Let the remote control get close to
control does
with the direction of the remote-
the air conditioner, and make sure
not work.
control receiver.
that the remote control directly faces
to the direction of the remote-control
receiver.
Batteries poor.
Replace batteries.
If problems not listed in the table occur or recommended solutions do not work, please
contact the service centre.
ERROR CODES
Fault Code
Fault Description
Fault Code
Fault Description
F1
Compressor IPM error
P5
AC undervoltage protection
F2
PFC/IPM error
P7
Defrost protection on coil tube
F3
Compressor start error
P8
Zero-crossing fault detection
F4
Compressor running out of step
PA
Return air sensor temperature
abnormal protection
F5
Location detection loop failure
PE
Abnormal refrigerant circulation
F6
PCB communication error
PH
Exhaust temperature protection
F8
Sensor on suction pipe error
E0
Sensor on suction pipe error
FA
Phase current overcurrent protection
E1
Temperature sensor error
FL
Water-full protection
E2
Sensor error on indoor coil tube
P1
Over-heat protection on top of
compressor
E3
DC fan Feedback failure
P2
Dc bus voltage Undervoltage protection
E5
Water-splash motor error
P3
AC Input voltage protection
E8
Fan feedback fault
P4
AC over-current protection
EE
EE error
Summary of Contents for BC10MBKL2101F
Page 32: ...TECHNISCHE ZEICHNUNG MODELL BC10MBKL2101F...
Page 35: ...34 35 D...
Page 66: ...TECHNICAL DRAWING MODEL BC10MBKL2101F...
Page 69: ...68 69 E...
Page 70: ...NOTE...
Page 71: ...70 71 E NOTE...
Page 72: ...Schuss Home Electronic GmbH Scheringgasse 3 A 1140 Wien Tel 43 1 97 0 21 0...